EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Left ventricular mechanical dispersion as a predictor of the need for pacemaker implantation after transcatheter aortic valve implantation: MeDiPace TAVI study

Esra Kaya iD, Kristoffer Andresen, Øyvind H Lie, Lars Aaberge, Kristina H Haugaa, Thor Edvardsen iD, Helge Skulstad iD

European Heart Journal - Cardiovascular Imaging · 2024

DOI: 10.1093/ehjci/jead315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Heart Journal - Cardiovascular Imaging, 2024. Verfasst von Esra Kaya und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Clinic of Heart, Lung and Vessel Disease, Rikshospitalet, Oslo University Hospital, Sognsvannsveien 20, 0372 Oslo, Norway. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Pacemaker, Artificial, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: European Association of Cardiovascular Imaging.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Permanent pacemaker (PM) implantation is common after transcatheter aortic valve implantation (TAVI). Left ventricular mechanical dispersion (MeDi) by speckle tracking echocardiography is a marker of fibrosis that causes alterations in the conduction system. We hypothesized that MeDi can be a predictor of the need for PM implantation after TAVI. Methods and results Consecutively, 200 TAVI patients were enrolled. Transthoracic echocardiography and electrocardiography examinations were recorded before TAVI to evaluate global longitudinal strain (GLS), MeDi, and conduction disturbances. PM implantation information was obtained 3 months after TAVI. Patients were stratified into PM or no PM group. Mean age was 80 + 7 years (44% women). Twenty-nine patients (16%) received PM. MeDi, QRS duration, existence of right bundle branch abnormality (RBBB), and first-degree atrioventricular (AV) block were significantly different between groups. MeDi was 57 ± 15 ms and 48 ± 12 ms in PM and no PM groups, respectively (P < 0.001). In multivariate analysis, MeDi predicted the need for PM after TAVI independently of GLS, QRS duration, RBBB, and first-degree AV block [odds ratio (OR): 1.73, 95% confidence interval (CI): 1.22–2.45] with an area under the curve (AUC) of 0.68 in receiver operating characteristic (ROC) curves. Moreover, RBBB was an independent predictor of PM need after TAVI (OR: 8.98, 95% CI: 1.78–45.03). When added to RBBB, MeDi had an incremental predictive value with an AUC of 0.73 in ROC curves (P = 0.01).

Conclusion

MeDi may be used as an echocardiographic functional predictor of the need for PM after TAVI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisPacemaker, ArtificialHeart Valve Prosthesis ImplantationAtrioventricular BlockHeart Valve ProsthesisHumansFemaleAgedAged, 80 and overMaleTreatment OutcomeAortic Valve

Stichwörter der Autor:innen

PM implantationglobal longitudinal strainmechanical dispersionspeckle tracking echocardiographytranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiology, Clinic of Heart, Lung and Vessel Disease, Rikshospitalet, Oslo University Hospital, Sognsvannsveien 20, 0372 Oslo, Norway.
  • Clinic of Heart, Lung and Vessel Disease, Rikshospitalet, Institude for Surgical Research, Oslo University Hospital, Sognsvannsveien 20,0372 Oslo, Norway.
  • PROCARDIO-Center for Innovation, Clinic of Heart, Lung and Vessel Disease, Rikshospitalet, Oslo University Hospital, Oslo, Norway.
  • Institude of Clinical Medicine, University of Oslo, Blindern 0318, Oslo, Norway.

ORCID-Profile: Esra Kaya, Thor Edvardsen, Helge Skulstad

Förderung

  • European Association of Cardiovascular Imaging

Zitieren

APA

Kaya, E., Andresen, K., Lie, Ø. H., Aaberge, L., Haugaa, K. H., Edvardsen, T., & Skulstad, H. (2024). Left ventricular mechanical dispersion as a predictor of the need for pacemaker implantation after transcatheter aortic valve implantation: MeDiPace TAVI study. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jead315

Vancouver

Kaya E, Andresen K, Lie ØH, Aaberge L, Haugaa KH, Edvardsen T, et al. Left ventricular mechanical dispersion as a predictor of the need for pacemaker implantation after transcatheter aortic valve implantation: MeDiPace TAVI study. European Heart Journal - Cardiovascular Imaging. 2024. doi:10.1093/ehjci/jead315

BibTeX
@article{Kaya2024,
  author = {Kaya, Esra and Andresen, Kristoffer and Lie, Øyvind H and Aaberge, Lars and Haugaa, Kristina H and Edvardsen, Thor and Skulstad, Helge},
  title = {Left ventricular mechanical dispersion as a predictor of the need for pacemaker implantation after transcatheter aortic valve implantation: MeDiPace TAVI study},
  journal = {European Heart Journal - Cardiovascular Imaging},
  year = {2024},
  doi = {10.1093/ehjci/jead315}
}
Kostenlos starten →