Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence: clinical validation in real time and large databases
European Heart Journal - Cardiovascular Imaging · 22.02.2024 · 25 (3) · 383-395
DOI: 10.1093/ehjci/jead280 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Heart Journal - Cardiovascular Imaging, online erschienen am 26.10.2023. Verfasst von Sindre Olaisen und 13 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Innovative Ultrasound Solutions, Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Prinsesse …. Hauptthemen laut MEDLINE: Artificial Intelligence, Ventricular Dysfunction, Left. Die Arbeit wurde bisher 64-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Norwegian University of Science and Technology, Research Council of Norway, Central Norway Health Authority.
Abstract (Originalsprache)
Aims
Echocardiography is a cornerstone in cardiac imaging, and left ventricular (LV) ejection fraction (EF) is a key parameter for patient management. Recent advances in artificial intelligence (AI) have enabled fully automatic measurements of LV volumes and EF both during scanning and in stored recordings. The aim of this study was to evaluate the impact of implementing AI measurements on acquisition and processing time and test–retest reproducibility compared with standard clinical workflow, as well as to study the agreement with reference in large internal and external databases. Methods and results Fully automatic measurements of LV volumes and EF by a novel AI software were compared with manual measurements in the following clinical scenarios: (i) in real time use during scanning of 50 consecutive patients, (ii) in 40 subjects with repeated echocardiographic examinations and manual measurements by 4 readers, and (iii) in large internal and external research databases of 1881 and 849 subjects, respectively. Real-time AI measurements significantly reduced the total acquisition and processing time by 77% (median 5.3 min, P < 0.001) compared with standard clinical workflow. Test–retest reproducibility of AI measurements was superior in inter-observer scenarios and non-inferior in intra-observer scenarios. AI measurements showed good agreement with reference measurements both in real time and in large research databases.
Conclusion
The software reduced the time taken to perform and volumetrically analyse routine echocardiograms without a decrease in accuracy compared with experts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Innovative Ultrasound Solutions, Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Prinsesse Kristinas Gate 3, 7030 Trondheim, Norway.
- Medical Image Analysis, Health Research, SINTEF Digital, Trondheim, Norway.
- Clinic of Cardiology, St.Olavs Hospital, Trondheim University Hospital, Prinsesse Kristinas Gate 3, 7030 Trondheim, Norway.
- Department of Cardiology, University Hospital of North Norway, Tromsø, Norway.
- Institute for Clinical Medicine, UiT, The Arctic University of Norway, Tromsø, Norway.
- Department of Cardiology, University Hospital of North Norway, UNN Harstad, Tromsø, Norway.
ORCID-Profile: Sindre Olaisen, Erik Smistad, Torvald Espeland, David Pasdeloup, Espen Holte, Havard Dalen
Förderung
- Norwegian University of Science and Technology
- Research Council of Norway
- Central Norway Health Authority
- St. Olavs University Hospital
- Nord-Trøndelag Hospital Trust
- Simon Fougner Hartmann Family Foundation
Zitieren
APA
Olaisen, S., Smistad, E., Espeland, T., Hu, J., Pasdeloup, D., Østvik, A., Aakhus, S., Rösner, A., Malm, S., Stylidis, M., Holte, E., Grenne, B., Løvstakken, L., & Dalen, H. (2024). Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence: clinical validation in real time and large databases. European Heart Journal - Cardiovascular Imaging, 25(3), 383-395. https://doi.org/10.1093/ehjci/jead280
Vancouver
Olaisen S, Smistad E, Espeland T, Hu J, Pasdeloup D, Østvik A, et al. Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence: clinical validation in real time and large databases. European Heart Journal - Cardiovascular Imaging. 2024;25(3):383-395. doi:10.1093/ehjci/jead280
BibTeX
@article{Olaisen2024,
author = {Olaisen, Sindre and Smistad, Erik and Espeland, Torvald and Hu, Jieyu and Pasdeloup, David and Østvik, Andreas and Aakhus, Svend and Rösner, Assami and Malm, Siri and Stylidis, Michael and Holte, Espen and Grenne, Bjørnar and Løvstakken, Lasse and Dalen, Havard},
title = {Automatic measurements of left ventricular volumes and ejection fraction by artificial intelligence: clinical validation in real time and large databases},
journal = {European Heart Journal - Cardiovascular Imaging},
year = {2024},
volume = {25},
number = {3},
pages = {383--395},
doi = {10.1093/ehjci/jead280}
}
EUVIMED