High-definition blood flow imaging improves quantification of left ventricular volumes and ejection fraction
European Heart Journal - Cardiovascular Imaging · 2024
DOI: 10.1093/ehjci/jead245 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Heart Journal - Cardiovascular Imaging, 2024. Verfasst von Francisco Gama und 6 weiteren Autor:innen. Beteiligte Einrichtung: St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK. Hauptthemen laut MEDLINE: Ventricular Dysfunction, Left, Echocardiography, Three-Dimensional. Die Arbeit nennt 12 Literaturangaben. Gefördert von: British Heart Foundation.
Abstract (Originalsprache)
Aims
The accuracy and reproducibility of echocardiography to quantify left ventricular ejection fraction (LVEF) is limited due to image quality. High-definition blood flow imaging is a new technique which improves cavity delineation without the need for medication or intravenous access. We sought to examine the impact of high-definition blood flow imaging on accuracy and reproducibility of LV systolic function assessment. Methods and results Prospective observational study of consecutive patients undergoing 2D and 3D transthoracic echocardiography (TTE), high-definition blood flow imaging, and cardiac magnetic resonance (CMR) within 1 h of each other. Left ventricular systolic function characterized by left ventricular end-systolic volumes and left ventricular end-diastolic volumes and LVEF were measured. Seventy-six patients were included. Correlation of 2D TTE with CMR was modest (r = 0.68) with a worse correlation in patients with three or more segments not visualized (r = 0.58). High-definition blood flow imaging was feasible in all patients, and the correlation of LVEF with CMR was excellent (r = 0.88). The differences between 2D, high-definition blood flow, and 3D TTE compared to CMR were 5 ± 9%, 2 ± 5%, and 1 ± 3%, respectively. The proportion of patients where the grade of LV function was correctly classified improved from 72.3% using 2D TTE to 92.8% using high-definition blood flow imaging. 3D TTE also had excellent correlation with CMR (r = 0.97) however was only feasible in 72.4% of patients.
Conclusion
High-definition blood flow imaging is highly feasible and significantly improves the diagnostic accuracy and grading of LV function compared to 2D echocardiography.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK.
- Hospital Santa Cruz, Lisboa, Portugal.
- Hospital Vila Franca de Xira, Lisboa, Portugal.
- Institute of Cardiovascular Science, UCL, 62 Huntley Street, London, WC1E 6DD, UK.
- William Harvey Institute, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK.
ORCID-Profile: Thomas A Treibel, Sanjeev Bhattacharyya
Förderung
- British Heart Foundation
Zitieren
APA
Gama, F., Custódio, P., Tsagkridi, A., Moon, J., Lloyd, G., Treibel, T. A., & Bhattacharyya, S. (2024). High-definition blood flow imaging improves quantification of left ventricular volumes and ejection fraction. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jead245
Vancouver
Gama F, Custódio P, Tsagkridi A, Moon J, Lloyd G, Treibel TA, et al. High-definition blood flow imaging improves quantification of left ventricular volumes and ejection fraction. European Heart Journal - Cardiovascular Imaging. 2024. doi:10.1093/ehjci/jead245
BibTeX
@article{Gama2024,
author = {Gama, Francisco and Custódio, Pedro and Tsagkridi, Aliki and Moon, James and Lloyd, Guy and Treibel, Thomas A and Bhattacharyya, Sanjeev},
title = {High-definition blood flow imaging improves quantification of left ventricular volumes and ejection fraction},
journal = {European Heart Journal - Cardiovascular Imaging},
year = {2024},
doi = {10.1093/ehjci/jead245}
}
EUVIMED