Fachartikel in der Zeitschrift European Heart Journal - Cardiovascular Imaging, 2023. Verfasst von Victoria Vilalta und 3 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitari Germans Trias i Pujol, Badalona, Carretera de Canyet, s/n, Barcelona 08916, Spain. Hauptthemen laut MEDLINE: Atrial Appendage, Cardiac Surgical Procedures, Heart Valve Prosthesis Implantation, Atrial Fibrillation.
Abstract (Originalsprache)
Treatment of severe degenerative mitral stenosis or regurgitation due to annular calcification (MAC) remains challenging. Surgical implantation of balloon expandable transcatheter heart valves (THVs) has been proposed as a hybrid technique that reduces the risk of left ventricular outflow tract (LVOT) obstruction and the risk of paravalvular leak (PVL). The mitral leaflets are resected, and the THV is sutured to a pericardial skirt that is sutured to the left atrial wall surrounding the calcified mitral annulus. A 78-year-old patient with the history of surgical aortic valve replacement and severe mitral regurgitation and severe MAC was admitted with heart failure. Computed tomography predicted a high risk of LVOT obstruction during transcatheter mitral valve replacement. Therefore, a 23 mm Edwards Sapien 3 was surgically implanted supra-annular with a sutured pericardial skirt under direct vision. The intra-operative transoesophageal echocardiogram showed a severe ventricular jet opening through an anchoring patch defect in the posterior zone to the left atrial appendage (LAA) (Panel A). Six months later, the patient presented with refractory heart failure due to a partial detachment of the auricular pericardial patch (Panel B), and percutaneous closure of the PVL was planned. While the jet of the PVL was directed towards the LAA, an Amplatzer Amulet 25 mm was implanted in the LAA holding the patch against the atrial wall (Panel C). The patient had a favourable recovery with resolution of heart failure symptoms, and the echocardiography showed a good positioning of the LAA occlusion device and a complete sealing of the leak. Although this ‘bail-out’ procedure had been previously described, PVL due to pericardium skirt detachment was not reported, and this case illustrates a good percutaneous solution when PVL is located in the lateral wall. Funding: None declared. Data availability: No new data were generated or analysed in support of this research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Hospital Universitari Germans Trias i Pujol, Badalona, Carretera de Canyet, s/n, Barcelona 08916, Spain.
ORCID-Profile: Victoria Vilalta
Zitieren
APA
Vilalta, V., Fernández-Nofrerias, E., Carrillo, X., & Delgado, V. (2023). Transcatheter mitral valve leak closure with left atrial appendage closure device: kill two birds with one stone. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jead232
Vancouver
Vilalta V, Fernández-Nofrerias E, Carrillo X, Delgado V. Transcatheter mitral valve leak closure with left atrial appendage closure device: kill two birds with one stone. European Heart Journal - Cardiovascular Imaging. 2023. doi:10.1093/ehjci/jead232
BibTeX
@article{Vilalta2023,
author = {Vilalta, Victoria and Fernández-Nofrerias, Eduard and Carrillo, Xavier and Delgado, Victoria},
title = {Transcatheter mitral valve leak closure with left atrial appendage closure device: kill two birds with one stone},
journal = {European Heart Journal - Cardiovascular Imaging},
year = {2023},
doi = {10.1093/ehjci/jead232}
}
EUVIMED