Device-related adverse events and flow capacity of percutaneous ventricular assist devices
European Heart Journal: Acute Cardiovascular Care · 2025
DOI: 10.1093/ehjacc/zuae132 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Heart Journal: Acute Cardiovascular Care, 2025. Verfasst von Yuki Ikeda und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-Ku, Sagamihara, Kanagawa 252-0374, Japan. Hauptthemen laut MEDLINE: Heart-Assist Devices, Postoperative Complications, Registries, Shock, Cardiogenic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Themen: Patientensicherheit
Abstract (Originalsprache)
Aims
Complication management is crucial in patients receiving mechanical circulatory devices. However, there are limited data on the association between the risks of complications and device type in patients with percutaneous ventricular assist devices (PVAD). Methods and results The Japanese registry for PVAD (J-PVAD) is a nationwide ongoing registry that enrols consecutive patients with cardiogenic shock treated with PVAD. We analysed 5717 patients in the J-PVAD from 1 February 2020 to 31 December 2022, to compare the incident risks of device-related problems and all-cause mortality within 30 days after PVAD introduction based on flow capacities of first-line PVAD (low: Impella 2.5/CP, n = 5375; high: Impella 5.0/5.5, n = 342). The overall incidence of major device-related problems, including haemolysis, major bleeding, kidney injury, sepsis, and pump stop, was 13%, 21%, 7%, 3%, and 1%, respectively. The all-cause mortality rate was 34%. The incident risks of haemolysis [hazard ratio (HR) 0.38, 95% confidence interval (CI) 0.24–0.58], kidney injury (HR 0.32, 95% CI 0.18–0.57), and pump stop (HR 0.38, 95% CI 0.16–0.91) were lower in patients with high-flow PVAD compared with those with low-flow PVAD. The risks of major bleeding or sepsis did not differ significantly between groups. The risk of all-cause mortality was lower in patients with high-flow PVAD compared with those with low-flow PVAD (HR 0.79, 95% CI 0.65–0.96).
Conclusion
Compared with those with low-flow PVAD, patients with high-flow PVAD had lower incident risks of device-related problems, including haemolysis, kidney injury, and pump stop, as well as lower risk of all-cause mortality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-Ku, Sagamihara, Kanagawa 252-0374, Japan.
ORCID-Profile: Yuki Ikeda, Shunsuke Ishii, Takeru Nabeta, Junya Ako
Zitieren
APA
Ikeda, Y., Ishii, S., Nakahara, S., Iikura, S., Fujita, T., Iida, Y., Nabeta, T., Sato, N., & Ako, J. (2025). Device-related adverse events and flow capacity of percutaneous ventricular assist devices. European Heart Journal: Acute Cardiovascular Care. https://doi.org/10.1093/ehjacc/zuae132
Vancouver
Ikeda Y, Ishii S, Nakahara S, Iikura S, Fujita T, Iida Y, et al. Device-related adverse events and flow capacity of percutaneous ventricular assist devices. European Heart Journal: Acute Cardiovascular Care. 2025. doi:10.1093/ehjacc/zuae132
BibTeX
@article{Ikeda2025,
author = {Ikeda, Yuki and Ishii, Shunsuke and Nakahara, Shohei and Iikura, Saeko and Fujita, Teppei and Iida, Yuichiro and Nabeta, Takeru and Sato, Nobuhiro and Ako, Junya},
title = {Device-related adverse events and flow capacity of percutaneous ventricular assist devices},
journal = {European Heart Journal: Acute Cardiovascular Care},
year = {2025},
doi = {10.1093/ehjacc/zuae132}
}
EUVIMED