Diagnostic Accuracy of Intestinal Ultrasound in the Detection of Intra-Abdominal Complications in Crohn’s Disease: A Systematic Review and Meta-Analysis
Journal of Crohn's and Colitis · 03.06.2024 · 18 (6) · 958-972
DOI: 10.1093/ecco-jcc/jjad215 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Crohn's and Colitis, online erschienen am 04.01.2024. Verfasst von Maarten J Pruijt und 5 weiteren Autor:innen. Beteiligte Einrichtung: Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Crohn Disease, Ultrasonography. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Amsterdam University Medical Centers.
Abstract (Originalsprache)
Background
Crohn’s disease [CD] is frequently associated with the development of strictures and penetrating complications. Intestinal ultrasound [IUS] is a non-invasive imaging modality ideal for point-of-care assessment. In this systematic review and meta-analysis we provide a current overview on the diagnostic accuracy of IUS and its advanced modalities in the detection of intra-abdominal complications in CD compared to endoscopy, cross-sectional imaging, surgery, and pathology.
Method
We conducted a literature search for studies describing the diagnostic accuracy of IUS in adult patients with CD-related intra-abdominal complications. Quality of the included studies was assessed with the QUADAS-2 tool. Meta-analysis was performed for both conventional IUS [B-mode] and oral contrast IUS [SICUS].
Results
Of the 1498 studies we identified, 68 were included in this review and 23 studies [3863 patients] were used for the meta-analysis. Pooled sensitivities and specificities for strictures, inflammatory masses, and fistulas by B-mode IUS were 0.81 and 0.90, 0.87 [sensitivities] and 0.95, and 0.67 and 0.97 [specificities], respectively. Pooled overall log diagnostic odds ratios were 3.56, 3.97 and 3.84, respectively. Pooled sensitivity and specificity of SICUS were 0.94 and 0.95, 0.91 and 0.97 [sensitivities], and 0.90 and 0.94 [specificities], respectively. The pooled overall log diagnostic odds ratios of SICUS were 4.51, 5.46, and 4.80, respectively.
Conclusion
IUS is accurate for the diagnosis of intra-abdominal complications in CD. As a non-invasive, point-of-care modality, IUS is recommended as the first-line imaging tool if there is a suspicion of CD-related intra-abdominal complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Amsterdam UMC, University of Amsterdam, Gastroenterology and Hepatology, Amsterdam, The Netherlands.
- Amsterdam UMC, University of Amsterdam, Medical Library, Amsterdam, The Netherlands.
ORCID-Profile: Maarten J Pruijt, Floris A E de Voogd
Förderung
- Amsterdam University Medical Centers
Zitieren
APA
Pruijt, M. J., de Voogd, F. A. E., Montazeri, N. S. M., van Etten-Jamaludin, F. S., D'Haens, G. R., & Gecse, K. B. (2024). Diagnostic Accuracy of Intestinal Ultrasound in the Detection of Intra-Abdominal Complications in Crohn’s Disease: A Systematic Review and Meta-Analysis. Journal of Crohn's and Colitis, 18(6), 958-972. https://doi.org/10.1093/ecco-jcc/jjad215
Vancouver
Pruijt MJ, de Voogd FAE, Montazeri NSM, van Etten-Jamaludin FS, D'Haens GR, Gecse KB. Diagnostic Accuracy of Intestinal Ultrasound in the Detection of Intra-Abdominal Complications in Crohn’s Disease: A Systematic Review and Meta-Analysis. Journal of Crohn's and Colitis. 2024;18(6):958-972. doi:10.1093/ecco-jcc/jjad215
BibTeX
@article{Pruijt2024,
author = {Pruijt, Maarten J and de Voogd, Floris A E and Montazeri, Nahid S M and van Etten-Jamaludin, Faridi S and D'Haens, Geert R and Gecse, Krisztina B},
title = {Diagnostic Accuracy of Intestinal Ultrasound in the Detection of Intra-Abdominal Complications in Crohn’s Disease: A Systematic Review and Meta-Analysis},
journal = {Journal of Crohn's and Colitis},
year = {2024},
volume = {18},
number = {6},
pages = {958--972},
doi = {10.1093/ecco-jcc/jjad215}
}
EUVIMED