EUVIMEDEUVIMED entdecken
Multizentrische StudieValidierungsstudie

Detection of Barrett’s esophagus through exhaled breath using an electronic nose device: a multicenter validation study

Lotte J Huibertse iD, Yonne Peters, Ruud W M Schrauwen, Adriaan C I T L Tan, Niek Warringa, Jordy P W Burger, Peter D Siersema

Diseases of the Esophagus · 02.11.2026 · 39 (6)

DOI: 10.1093/dote/doag124 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Diseases of the Esophagus, online erschienen am 13.11.2026. Verfasst von Lotte J Huibertse und 6 weiteren Autor:innen. Beteiligte Einrichtung: Radboudumc Research Institute for Medical Innovation, Department of Gastroenterology and Hepatology, Radboud University Medical Center, Nijmegen, the…. Hauptthemen laut MEDLINE: Electronic Nose, Barrett Esophagus, Volatile Organic Compounds. Die Arbeit nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Esophageal adenocarcinoma incidence has risen dramatically in the Western world over the past 30 years, particularly driven by gastroesophageal reflux disease (GERD) and Barrett’s esophagus (BE). We aimed to assess whether Volatile Organic Compound (VOC) breath testing can predict BE and to validate its performance in independent cohorts including participants with BE, participants with GERD, and controls. Participants aged ≥18 years referred for gastroscopy between August 2017 and July 2022, were eligible for inclusion. The diagnostic accuracy of VOC breath testing was assessed using four machine learning algorithms (MLAs): (1) random forest, (2) extremely randomized trees, (3) eXtreme Gradient Boosting (XGBoost), and (4) convolutional neural network. Patient tolerability and patient acceptability of breath testing were secondary outcome measures. A total of 1079 participants were included, 602 (55.8%) in the training cohort and 477 (44.2%) in the validation cohort. In the training cohort, XGBoost was the best performing MLA in differentiating BE from GERD and controls (area under the receiver operating characteristic [AUROC] 0.892 [95% CI, 0.862–0.921]). However, in the validation cohort, the performance of XGBoost markedly declined (AUROC 0.530 [95% CI, 0.472–0.589]). Median tolerability score was 2.00 with 0 ‘no discomfort’ and 10 ‘worst discomfort imaginable’, and median acceptability score was 8.00 with 0 ‘worst experience’ and 10 ‘best experience’. VOC breath testing in its current form does not provide additional diagnostic value for BE screening; however, based on the high degree of patient acceptability, further research on eNose technology seems justified.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electronic NoseBarrett EsophagusVolatile Organic CompoundsHumansBreath TestsFemaleMiddle AgedMaleAgedGastroesophageal RefluxAdultROC CurveReproducibility of Results

Stichwörter der Autor:innen

Barrett’s esophagusbreath testingelectronic nose devicescreeningvolatile organic compounds

Substanzen

Volatile Organic Compounds

Autor:innen und Institutionen

  • Radboudumc Research Institute for Medical Innovation, Department of Gastroenterology and Hepatology, Radboud University Medical Center, Nijmegen, the Netherlands.
  • Department of Gastroenterology and Hepatology, Bernhoven Hospital, Uden, the Netherlands.
  • Department of Gastroenterology and Hepatology, Canisius-Wilhelmina Hospital, Nijmegen, the Netherlands.
  • Department of Gastroenterology and Hepatology, Isala Hospital, Zwolle, the Netherlands.
  • Department of Gastroenterology and Hepatology, Rijnstate Hospital, Arnhem, the Netherlands.
  • Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam, the Netherlands.

ORCID-Profile: Lotte J Huibertse

Zitieren

APA

Huibertse, L. J., Peters, Y., Schrauwen, R. W. M., Tan, A. C. I. T. L., Warringa, N., Burger, J. P. W., & Siersema, P. D. (2026). Detection of Barrett’s esophagus through exhaled breath using an electronic nose device: a multicenter validation study. Diseases of the Esophagus, 39(6). https://doi.org/10.1093/dote/doag124

Vancouver

Huibertse LJ, Peters Y, Schrauwen RWM, Tan ACITL, Warringa N, Burger JPW, et al. Detection of Barrett’s esophagus through exhaled breath using an electronic nose device: a multicenter validation study. Diseases of the Esophagus. 2026;39(6). doi:10.1093/dote/doag124

BibTeX
@article{Huibertse2026,
  author = {Huibertse, Lotte J and Peters, Yonne and Schrauwen, Ruud W M and Tan, Adriaan C I T L and Warringa, Niek and Burger, Jordy P W and Siersema, Peter D},
  title = {Detection of Barrett’s esophagus through exhaled breath using an electronic nose device: a multicenter validation study},
  journal = {Diseases of the Esophagus},
  year = {2026},
  volume = {39},
  number = {6},
  doi = {10.1093/dote/doag124}
}
Kostenlos starten →