Analysis of reported adverse events with esophageal dilation devices: a 10-year FDA manufacturer and user facility device experience database study
Diseases of the Esophagus · 02.03.2026 · 39 (2)
DOI: 10.1093/dote/doag032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diseases of the Esophagus, online erschienen am 10.04.2026. Verfasst von Andrew C Stuart und 5 weiteren Autor:innen. Beteiligte Einrichtung: Paul L. Foster School of Medicine, Department of Medicine, Texas Tech University Health Sciences Center, El Paso, TX, USA. Hauptthemen laut MEDLINE: Dilatation, Equipment Failure, Esophageal Stenosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Themen: Patientensicherheit
Abstract (Originalsprache)
Esophageal dilation is a cornerstone therapeutic intervention in managing esophageal narrowing, using various types of dilation devices. While highly effective, it carries risks, including patient-related adverse events (PRAE) and device-related failures (DRF). Analysis of these complications is imperative for decision-making with the goal of enhancing procedural safety. Reports from the Manufacturer and User Facility Device Experience (MAUDE) database from January 2014 to June 2024 were analyzed. Although circulation numbers are unknown, event occurrence per device was compared using weighted averages of events and Poisson regression. A total of 1418 reports were identified, yielding 117 PRAE and 1845 DRF. The overall weighted average of PRAE was 0.07 (95% CI: 0.03, 0.11) per report, while DRF were 1.24 (95% CI: 1.13–1.36) per report. The most common PRAE was perforation (n = 32; 27%), with the most reports attributed to Rigiflex Pneumatic II (n = 13) and Savary-Giliard/American (n = 9). The most common DRFs pertained to material integrity issues which occur at relative rates 2.4 to 3.9 times higher than other device-related complications. About 117 PRAE reports were identified in the entire cohort. After excluding pneumatic dilation cases, it was determined that 70% (n = 71) of all PRAEs co-occurred with a material integrity issue. MAUDE analysis suggests variability in safety profiles across esophageal dilators. Perforation is the most reported PRAE across esophageal dilation procedures in general and may be linked to the co-occurrence of material integrity issues and aberrant guidewires in certain wire-guided polyvinyl dilators. To reduce PRAE occurrences, we encourage operators to recognize these patterns and their potential impact on adverse patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Paul L. Foster School of Medicine, Department of Medicine, Texas Tech University Health Sciences Center, El Paso, TX, USA.
- Division of Gastroenterology and Hepatology, Texas Tech University Health Sciences Center, El Paso, TX, USA.
- Center for Advanced Therapeutic Endoscopy, Porter Adventist Hospital, Centura Health, Denver, CO USA.
- Center for Integrated Biostatistics and Epidemiology, Department of Biomedical Informatics, Biostatistics, and Medical Epidemiology, University of Missouri School of Medicine, Columbia, MI, USA.
ORCID-Profile: Andrew C Stuart, Alok K Dwivedi
Zitieren
APA
Stuart, A. C., Tatro, E. S., Zuckerman, M. J., Adler, D. G., Dwivedi, A. K., & Elhanafi, S. E. (2026). Analysis of reported adverse events with esophageal dilation devices: a 10-year FDA manufacturer and user facility device experience database study. Diseases of the Esophagus, 39(2). https://doi.org/10.1093/dote/doag032
Vancouver
Stuart AC, Tatro ES, Zuckerman MJ, Adler DG, Dwivedi AK, Elhanafi SE. Analysis of reported adverse events with esophageal dilation devices: a 10-year FDA manufacturer and user facility device experience database study. Diseases of the Esophagus. 2026;39(2). doi:10.1093/dote/doag032
BibTeX
@article{Stuart2026,
author = {Stuart, Andrew C and Tatro, Eric S and Zuckerman, Marc J and Adler, Douglas G and Dwivedi, Alok K and Elhanafi, Sherif E},
title = {Analysis of reported adverse events with esophageal dilation devices: a 10-year FDA manufacturer and user facility device experience database study},
journal = {Diseases of the Esophagus},
year = {2026},
volume = {39},
number = {2},
doi = {10.1093/dote/doag032}
}
EUVIMED