EUVIMEDEUVIMED entdecken
Crossref

Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence

Maximilian Hinsen, Markus Kopp, Martin Zeilinger, Claudius S Mathy, Michael Uder, Andreas Greiser, Manuel Weber, Ines Willershausen, Konstantin Hellwig

Dentomaxillofacial Radiology · 29.10.2026

DOI: 10.1093/dmfr/twag068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, online erschienen am 29.10.2026. Verfasst von Maximilian Hinsen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of this study was to investigate the feasibility of low-field dental MRI in the evaluation of the inferior alveolar nerve (IAN) and the acceleration of image acquisition with a deep learning (DL)-based sequence. Therefore, overall image quality (OIQ), image artefacts and delineation of the IAN were investigated.

Methods

In this single-centre retrospective study, we enrolled 39 patients who underwent dental MRI using a dedicated dental coil on a 0.55 T MRI system. A conventional T1-weighted gradient-echo 3D sequence and a T1-weighted gradient-echo 3D sequence with advanced DL-based reconstruction were acquired. Both sequences were evaluated for OIQ, image artefacts in and conspicuity of the IAN using a Likert scale from 1 to 5. Interrater agreement was assessed using weighted Cohen’s κ coefficients. As quantitative measurements, the apparent signal-to-noise ratio (aSNR) and the diameter of the IAN were determined.

Results

Thirty-three examinations were included, OIQ was rated higher for the accelerated sequence compared with the conventional sequence for both readers (p < 0.01). Image artefacts were lower in the accelerated sequence for both readers (p < 0.001). Accordingly, the delineation of the IAN was improved for both sides (p < 0.001) in the accelerated sequence. Interrater agreement between readers was substantial/good to almost perfect/excellent across all measures. aSNR was increased in the accelerated sequence (p < 0.001), whereas IAN diameter did not differ.

Conclusions

This study demonstrates that a DL-accelerated T1-weighted gradient-echo 3D sequence for dental-dedicated MRI is feasible for imaging of the IAN with improved image quality while reducing acquisition time by 50%. Advances in Knowledge Reduction of scan time and superior image quality could help establish dental-dedicated MRI as a radiation-free alternative for dentomaxillofacial imaging.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencedeep learning-based image reconstructiondental MRIdental imagingmagnetic resonance imaging

Autor:innen und Institutionen

  • Institute of Radiology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany.
  • Siemens Healthineers AG, Erlangen, Germany.
  • Department of Oral and Cranio-Maxillofacial Surgery, Friedrich-Alexander-Universität Erlangen-Nuremberg, Glueckstrasse 11, Erlangen, Germany.
  • Department of Orthodontics and Orofacial Orthopedics, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany.

Zitieren

APA

Hinsen, M., Kopp, M., Zeilinger, M., Mathy, C. S., Uder, M., Greiser, A., Weber, M., Willershausen, I., & Hellwig, K. (2026). Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twag068

Vancouver

Hinsen M, Kopp M, Zeilinger M, Mathy CS, Uder M, Greiser A, et al. Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence. Dentomaxillofacial Radiology. 2026. doi:10.1093/dmfr/twag068

BibTeX
@article{Hinsen2026,
  author = {Hinsen, Maximilian and Kopp, Markus and Zeilinger, Martin and Mathy, Claudius S and Uder, Michael and Greiser, Andreas and Weber, Manuel and Willershausen, Ines and Hellwig, Konstantin},
  title = {Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence},
  journal = {Dentomaxillofacial Radiology},
  year = {2026},
  doi = {10.1093/dmfr/twag068}
}
Kostenlos starten →