EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative evaluation of direct and digital measurements of peri-implant defects using CBCT, ultrasound, and intraoral scanning

Mahmure Ayşe Tayman iD, Kıvanç Kamburoğlu iD, Esra Ece Çakmak iD

Dentomaxillofacial Radiology · 2026

DOI: 10.1093/dmfr/twag006 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Dentomaxillofacial Radiology, 2026. Verfasst von Mahmure Ayşe Tayman und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontology, Faculty of Dentistry, Ankara Yıldırım Beyazıt University, Ankara, 06010, Turkey. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Dental Implants. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the measurement accuracy of cone-beam computed tomography (CBCT), high-resolution ultrasound (US), and intraoral scanning (IOS) with the gold-standard direct method in the measurement of peri-implant bone defects.

Methods

Forty standard-threaded and 38 aggressive-threaded (Aggressor) implants—identical in diameter and length (4.3/10 mm) but differing in macro-thread design—were placed into bovine rib bones in vitro. Dehiscence, 2/3-wall, and 4-wall (circumferential) defects were prepared around the implants. Each defect was measured for maximum width, depth, and height using CBCT, US, IOS, and direct manual measurement. Analyses were performed using the general linear model (ANOVA). A P-value < .05 was considered statistically significant.

Results

Intra-operator and inter-operator agreement showed high reliability (Gage R&R below 10%). For maximum width, defect type (F = 894.81, P < .001), method (F = 6.76, P < .001), and implant type (F = 5.39, P = .021) were significant. For maximum depth, defect type (F = 861.12, P < .001) and method (F = 3.39, P = .018) were significant. For maximum height, method (F = 12.62, P < .001) and defect type (F = 38.91, P < .001) were significant. The model demonstrated high explanatory power for width (R2 = 75.9%) and depth (R2 = 76.6%) measurements but lower for height (R2 = 20.7%). CBCT provided the most consistent results relative to direct measurements, followed by US, whereas IOS showed greater deviations.

Conclusions

CBCT showed the highest agreement with direct measurements, followed by US, while IOS exhibited greater variability. Defect type and measurement modality were the primary determinants of accuracy. These findings indicate that CBCT and US can be considered reliable tools for assessing peri-implant bone defects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyDental ImplantsAnimalsCattleUltrasonographyReproducibility of ResultsIn Vitro TechniquesRibs

Stichwörter der Autor:innen

CBCTdiagnostic accuracyintraoral scannerperi-implant defectultrasound

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Periodontology, Faculty of Dentistry, Ankara Yıldırım Beyazıt University, Ankara, 06010, Turkey.
  • Dentomaxillofacial Radiology Department, Faculty of Dentistry, Ankara University, Ankara, 06500, Turkey.
  • Arel Oral and Dental Health Clinic, Etimesgut, Ankara 06793, Turkey.

ORCID-Profile: Mahmure Ayşe Tayman, Kıvanç Kamburoğlu, Esra Ece Çakmak

Zitieren

APA

Tayman, M. A., Kamburoğlu, K., & Çakmak, E. E. (2026). Comparative evaluation of direct and digital measurements of peri-implant defects using CBCT, ultrasound, and intraoral scanning. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twag006

Vancouver

Tayman MA, Kamburoğlu K, Çakmak EE. Comparative evaluation of direct and digital measurements of peri-implant defects using CBCT, ultrasound, and intraoral scanning. Dentomaxillofacial Radiology. 2026. doi:10.1093/dmfr/twag006

BibTeX
@article{Tayman2026,
  author = {Tayman, Mahmure Ayşe and Kamburoğlu, Kıvanç and Çakmak, Esra Ece},
  title = {Comparative evaluation of direct and digital measurements of peri-implant defects using CBCT, ultrasound, and intraoral scanning},
  journal = {Dentomaxillofacial Radiology},
  year = {2026},
  doi = {10.1093/dmfr/twag006}
}
Kostenlos starten →