Preparing for downstream tasks in artificial intelligence for dental radiology: a baseline performance comparison of deep learning models
Dentomaxillofacial Radiology · 2025
DOI: 10.1093/dmfr/twae056 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Dentomaxillofacial Radiology, 2025. Verfasst von Fara A Fernandes und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information and Communication Technology, University of Agder (UiA), 4879 Grimstad, Norway. Hauptthemen laut MEDLINE: Deep Learning, Cone-Beam Computed Tomography, Radiography, Dental, Artificial Intelligence. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: University of Agder.
Abstract (Originalsprache)
Objectives
To compare the performance of the convolutional neural network (CNN) with the vision transformer (ViT), and the gated multilayer perceptron (gMLP) in the classification of radiographic images of dental structures.
Methods
Retrospectively collected two-dimensional images derived from cone beam computed tomographic volumes were used to train CNN, ViT, and gMLP architectures as classifiers for four different cases. Cases selected for training the architectures were the classification of the radiographic appearance of maxillary sinuses, maxillary and mandibular incisors, the presence or absence of the mental foramen, and the positional relationship of the mandibular third molar to the inferior alveolar nerve canal. The performance metrics (sensitivity, specificity, precision, accuracy, and f1-score) and area under the curve (AUC)—receiver operating characteristic and precision-recall curves were calculated.
Results
The ViT with an accuracy of 0.74-0.98, performed on par with the CNN model (accuracy 0.71-0.99) in all tasks. The gMLP displayed marginally lower performance (accuracy 0.65-0.98) as compared to the CNN and ViT. For certain tasks, the ViT outperformed the CNN. The AUCs ranged from 0.77 to 1.00 (CNN), 0.80 to 1.00 (ViT), and 0.73 to 1.00 (gMLP) for all of the four cases.
Conclusions
The ViT and gMLP exhibited comparable performance with the CNN (the current state-of-the-art). However, for certain tasks, there was a significant difference in the performance of the ViT and gMLP when compared to the CNN. This difference in model performance for various tasks proves that the capabilities of different architectures may be leveraged.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Information and Communication Technology, University of Agder (UiA), 4879 Grimstad, Norway.
- Faculty European Campus Rottal-Inn, Deggendorf Institute of Technology (DIT), 84347 Pfarrkirchen, Germany.
ORCID-Profile: Fara A Fernandes
Förderung
- University of Agder
Zitieren
APA
Fernandes, F. A., Ge, M., Chaltikyan, G., Gerdes, M. W., & Omlin, C. W. (2025). Preparing for downstream tasks in artificial intelligence for dental radiology: a baseline performance comparison of deep learning models. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twae056
Vancouver
Fernandes FA, Ge M, Chaltikyan G, Gerdes MW, Omlin CW. Preparing for downstream tasks in artificial intelligence for dental radiology: a baseline performance comparison of deep learning models. Dentomaxillofacial Radiology. 2025. doi:10.1093/dmfr/twae056
BibTeX
@article{Fernandes2025,
author = {Fernandes, Fara A and Ge, Mouzhi and Chaltikyan, Georgi and Gerdes, Martin W and Omlin, Christian W},
title = {Preparing for downstream tasks in artificial intelligence for dental radiology: a baseline performance comparison of deep learning models},
journal = {Dentomaxillofacial Radiology},
year = {2025},
doi = {10.1093/dmfr/twae056}
}
EUVIMED