EUVIMEDEUVIMED entdecken
Vergleichsstudie

Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences

Tong Su, Xiaoli Zhu, Yu Chen iD, Zhentan Xu, Xingming Chen, Tao Zhang, Jinxia Zhu, Wei Liu, Xiaoye Wang, Zhuhua Zhang, Feng Feng, Zhengyu Jin

Dentomaxillofacial Radiology · 2025

DOI: 10.1093/dmfr/twae047 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Dentomaxillofacial Radiology, 2025. Verfasst von Tong Su und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, C…. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Head and Neck Neoplasms, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National High Level Hospital Clinical Research Funding, 2021 SKY Imaging Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare integrated slice-specific dynamic shimming (iShim) and simultaneous multi-slice (SMS) readout-segmented echo-planar imaging (RESOLVE) for diffusion-weighted imaging (DWI) of malignant head and neck tumours.

Methods

In this prospective study, 45 patients with malignant head and neck lesions underwent iShim- and SMS-RESOLVE imaging with two b-values (0, 800 s/mm2) at 3 T. Subjective image quality scores (lesion distortion, signal loss, fat saturation, and artefacts), quantitative lesion distortion, quantitative image quality [signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and SNR efficiency], ADC values, and total acquisition times of iShim- and SMS-RESOLVE imaging were evaluated and compared. Results iShim-RESOLVE (3 mins 7 s) had longer acquisition times than SMS-RESOLVE (2 min 1 s). iShim-RESOLVE images had much better overall image quality, geometric distortion, fat saturation, and signal loss than SMS-RESOLVE (P < .05). The quantitative tumour distortion in iShim-RESOLVE images was significantly smaller than those of SMS-RESOLVE, measured either with b = 0 s/mm2 or b = 800 s/mm2 (P < .05). Using the iShim technique, the SNR, CNR of high b-value images, and SNR efficiency were significantly higher than those of SMS-RESOLVE (P < .001). The ADC measurements with excellent agreement of iShim-RESOLVE images were higher than those of SMS-RESOLVE. Conclusions iShim-RESOLVE can decrease lesion distortion and improve overall image quality compared with SMS-RESOLVE in head and neck region. Advances in knowledge iShim-RESOLVE DWI may serve as a promising technique for reducing distortion and assessing head and neck lesions in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingHead and Neck NeoplasmsDiffusion Magnetic Resonance ImagingHumansProspective StudiesMiddle AgedFemaleMaleAgedAdultSignal-To-Noise RatioAged, 80 and over

Stichwörter der Autor:innen

diffusion-weighted imaginghead and neck imagingintegrated slice-specific dynamic shimmingreadout-segmented echo-planar imagingsimultaneous multi-slice

Autor:innen und Institutionen

  • Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
  • Department of Otolaryngology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
  • Department of Stomatology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
  • Department of MR Collaboration, Siemens Healthineers Ltd., Beijing 100102, China.
  • Department of Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen 518057, China.
  • Department of MR Clinical Marketing, Siemens Healthineers Ltd., Beijing 100102, China.

ORCID-Profile: Yu Chen

Förderung

  • National Natural Science Foundation of China
  • National High Level Hospital Clinical Research Funding
  • 2021 SKY Imaging Research Fund
  • Chinese International Medical Foundation

Zitieren

APA

Su, T., Zhu, X., Chen, Y., Xu, Z., Chen, X., Zhang, T., Zhu, J., Liu, W., Wang, X., Zhang, Z., Feng, F., & Jin, Z. (2025). Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twae047

Vancouver

Su T, Zhu X, Chen Y, Xu Z, Chen X, Zhang T, et al. Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences. Dentomaxillofacial Radiology. 2025. doi:10.1093/dmfr/twae047

BibTeX
@article{Su2025,
  author = {Su, Tong and Zhu, Xiaoli and Chen, Yu and Xu, Zhentan and Chen, Xingming and Zhang, Tao and Zhu, Jinxia and Liu, Wei and Wang, Xiaoye and Zhang, Zhuhua and Feng, Feng and Jin, Zhengyu},
  title = {Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences},
  journal = {Dentomaxillofacial Radiology},
  year = {2025},
  doi = {10.1093/dmfr/twae047}
}
Kostenlos starten →