Peracetic acid efficacy on disinfection of photostimulable phosphor plates
Dentomaxillofacial Radiology · 01.11.2024 · 53 (8) · 542-548
DOI: 10.1093/dmfr/twae046 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, online erschienen am 02.09.2024. Verfasst von Débora Costa Ruiz und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, 13414-903, Brazil. Hauptthemen laut MEDLINE: Peracetic Acid, Disinfection, Candida albicans, Acetic Acid. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Objectives
To evaluate the antimicrobial efficacy of white vinegar, acetic acid, and peracetic acid on photostimulable phosphor (PSP) plates disinfection, and to assess the disinfectant influence on the radiographic quality.
Methods
Eight PSP plates (Express system) were contaminated with Streptococcus mutans and Candida albicans. These plates were wiped with tissues without any substance, with white vinegar, acetic acid, and peracetic acid, followed by an agar imprint. Number of microbial colonies formed was recorded. Afterwards, the quality of radiographs was tested using the more efficient disinfectant. Before disinfection and after every five disinfections, two radiographs of an acrylic-block and two radiographs of an aluminium step-wedge were acquired for each plate. Density, noise, uniformity, and contrast were analysed. Three oral radiologists evaluated the images for the presence of artefacts. One-way analysis of variance compared changes on grey values among the disinfections (α = .05). Intra- and inter-examiner agreement for the presence of artefacts was calculated by weighted Kappa.
Results
Peracetic acid was the only one that eliminated both microorganisms. Density and uniformity decreased after 100 disinfections, and contrast changed without a pattern in the course of disinfections (P ≤ .05). Small artefacts were observed after 30 disinfections. Intra- and inter-examiner agreements were almost perfect.
Conclusions
Disinfection with peracetic acid eliminated both microorganisms. However, it also affected density, uniformity, and contrast of radiographs, and led to the formation of small artefacts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, SP, 13414-903, Brazil.
ORCID-Profile: Débora Costa Ruiz, Thaís Santos Cerqueira Ocampo, Eduardo Martinelli Franco, Iago Filipe Correia-Dantas, Renata de Oliveira Mattos-Graner, Francisco Haiter-Neto, Deborah Queiroz Freitas
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Ruiz, D. C., Ocampo, T. S. C., Franco, E. M., Correia-Dantas, I. F., Mattos-Graner, R. O., Haiter-Neto, F., & Freitas, D. Q. (2024). Peracetic acid efficacy on disinfection of photostimulable phosphor plates. Dentomaxillofacial Radiology, 53(8), 542-548. https://doi.org/10.1093/dmfr/twae046
Vancouver
Ruiz DC, Ocampo TSC, Franco EM, Correia-Dantas IF, Mattos-Graner RO, Haiter-Neto F, et al. Peracetic acid efficacy on disinfection of photostimulable phosphor plates. Dentomaxillofacial Radiology. 2024;53(8):542-548. doi:10.1093/dmfr/twae046
BibTeX
@article{Ruiz2024,
author = {Ruiz, Débora Costa and Ocampo, Thaís Santos Cerqueira and Franco, Eduardo Martinelli and Correia-Dantas, Iago Filipe and Mattos-Graner, Renata de Oliveira and Haiter-Neto, Francisco and Freitas, Deborah Queiroz},
title = {Peracetic acid efficacy on disinfection of photostimulable phosphor plates},
journal = {Dentomaxillofacial Radiology},
year = {2024},
volume = {53},
number = {8},
pages = {542--548},
doi = {10.1093/dmfr/twae046}
}
EUVIMED