The influence of different cheek and lip retractors and emissivity on intraoral infrared thermography
Dentomaxillofacial Radiology · 01.09.2024 · 53 (6) · 417-422
DOI: 10.1093/dmfr/twae025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, online erschienen am 29.05.2024. Verfasst von Layrlla Kateriny Moura Oliveira Lopes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, State University of Paraíba, Campina Grande 58429-500, Brazil. Hauptthemen laut MEDLINE: Thermography, Lip, Cheek, Infrared Rays. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil.
Abstract (Originalsprache)
Objectives
To assess the influence of two conventional and one adapted cheek and lip retractors and three emissivity setting values on intraoral infrared thermography (IT) temperature values.
Methods
The sample was composed by 50 volunteers. Three cheek and lip retractors were tested: Group 1—flex retractor (FR); Group 2—FR adapted with Styrofoam; Group 3—U-type retractor (UR) for cheek and lip. All thermograms were acquired using FLIR T650 infrared camera. A set of three thermograms in frontal norm were acquired for each lip and cheek retractor at 0.91, 0.96, and 0.98ε, with an interval of 15 min between each set of images to avoid thermal interference. All images were assessed by two observers. The ROIs’ mean temperature of the four upper incisors was recorded. Two-way ANOVA and Sidak post-test were used for data assessment with a significance level of 5%.
Results
Group 3 showed higher mean temperature than Groups 1 and 2 at all emissivity settings for all assessed teeth (P < .05). 0.91ε showed higher temperature than 0.96ε and 0.98ε for all assessed variables (P < .01). Contralateral teeth assessed using Group 3 at 0.91ε showed statistical differences between each other (P < .05). No statistical difference was observed between contralateral teeth assessed using Groups 1 and 2 at 0.96ε and 0.98ε (P > .05).
Conclusions
The choice of cheek and lip retractor and emissivity setting can interfere on intraoral IT temperature values. U-type cheek and lip retractor and 0.91ε setting should not be used for IT image acquisition when assessing dental tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dentistry, State University of Paraíba, Campina Grande 58429-500, Brazil.
- Center for Strategic Technologies in Health, State University of Paraíba, Campina Grande 58429-500, Brazil.
- College of Dentistry, University of Saskatchewan, Saskatoon S7N 5E5, Canada.
ORCID-Profile: Layrlla Kateriny Moura Oliveira Lopes, Rodolfo Ramos Castelo Branco, Rafaela Pequeno Reis Sousa, Elisa Diniz de Lima, Diego Filipe Bezerra Silva, Daniela Pita de Melo
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil
Zitieren
APA
Moura Oliveira Lopes, L. K., Ramos Castelo Branco, R., Pequeno Reis Sousa, R., Diniz de Lima, E., Bezerra Silva, D. F., & Pita de Melo, D. (2024). The influence of different cheek and lip retractors and emissivity on intraoral infrared thermography. Dentomaxillofacial Radiology, 53(6), 417-422. https://doi.org/10.1093/dmfr/twae025
Vancouver
Moura Oliveira Lopes LK, Ramos Castelo Branco R, Pequeno Reis Sousa R, Diniz de Lima E, Bezerra Silva DF, Pita de Melo D. The influence of different cheek and lip retractors and emissivity on intraoral infrared thermography. Dentomaxillofacial Radiology. 2024;53(6):417-422. doi:10.1093/dmfr/twae025
BibTeX
@article{MouraOliveiraLopes2024,
author = {Moura Oliveira Lopes, Layrlla Kateriny and Ramos Castelo Branco, Rodolfo and Pequeno Reis Sousa, Rafaela and Diniz de Lima, Elisa and Bezerra Silva, Diego Filipe and Pita de Melo, Daniela},
title = {The influence of different cheek and lip retractors and emissivity on intraoral infrared thermography},
journal = {Dentomaxillofacial Radiology},
year = {2024},
volume = {53},
number = {6},
pages = {417--422},
doi = {10.1093/dmfr/twae025}
}
EUVIMED