EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of quantitative radiomorphometric predictors of healthy and MRONJ-affected bone using panoramic radiography and cone-beam CT

Elif Aslan iD, Erinc Onem iD, Ali Mert iD, B Guniz Baksi iD

Dentomaxillofacial Radiology · 2024

DOI: 10.1093/dmfr/twae024 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Dentomaxillofacial Radiology, 2024. Verfasst von Elif Aslan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Radiology, Ege University School of Dentistry, Izmir, 35040, Turkey. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Radiography, Panoramic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To determine the most distinctive quantitative radiomorphometric parameter(s) for the detection of MRONJ-affected bone changes in panoramic radiography (PR) and cone-beam CT (CBCT).

Methods

PR and sagittal CBCT slices of 24 MRONJ patients and 22 healthy controls were used for the measurements of mandibular cortical thickness (MCT), fractal dimension (FD), lacunarity, mean gray value (MGV), bone area fraction (BA/TA), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N). MCT was measured in the mental foramen region. While FD and lacunarity were measured on mandibular trabecular and cortical regions-of-interest (ROIs), the remaining parameters were measured on trabecular ROIs. The independent samples t-test was used to compare the measurements between the MRONJ and control groups for both imaging modalities (P = .05).

Results

MCT was the only parameter that differentiated MRONJ-affected bone in both PR and CBCT (P < .05). None of the remaining parameters revealed any difference for MRONJ-affected bone in CBCT (P > .05). FD, lacunarity, MGV, BA/TA, and Tb.Sp could distinguish MRONJ-affected trabecular bone in PR (P < .05). The correspondent ROI for both imaging methods that was reliable for detecting MRONJ-affected bone was the trabecular bone distal to the mental foramen above the inferior alveolar canal (ROI-3).

Conclusions

MCT is a reliable parameter for the discrimination of MRONJ-affected bone in both PR and CBCT images. PR may be used to detect MRONJ-affected trabecular bone using FD, lacunarity, MGV, BA/TA, and Tb.Sp measurements as well.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyRadiography, PanoramicHumansFemaleMaleMiddle AgedCase-Control StudiesAgedBisphosphonate-Associated Osteonecrosis of the JawAdultMandibleFractals

Stichwörter der Autor:innen

cone-beam CTmedication-related osteonecrosis of the jawspanoramic radiographyquantitative bone parameters

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Radiology, Ege University School of Dentistry, Izmir, 35040, Turkey.
  • Department of Statistics, Ege University School of Science, Izmir, 35040, Turkey.

ORCID-Profile: Elif Aslan, Erinc Onem, Ali Mert, B Guniz Baksi

Zitieren

APA

Aslan, E., Onem, E., Mert, A., & Baksi, B. G. (2024). Comparison of quantitative radiomorphometric predictors of healthy and MRONJ-affected bone using panoramic radiography and cone-beam CT. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twae024

Vancouver

Aslan E, Onem E, Mert A, Baksi BG. Comparison of quantitative radiomorphometric predictors of healthy and MRONJ-affected bone using panoramic radiography and cone-beam CT. Dentomaxillofacial Radiology. 2024. doi:10.1093/dmfr/twae024

BibTeX
@article{Aslan2024,
  author = {Aslan, Elif and Onem, Erinc and Mert, Ali and Baksi, B Guniz},
  title = {Comparison of quantitative radiomorphometric predictors of healthy and MRONJ-affected bone using panoramic radiography and cone-beam CT},
  journal = {Dentomaxillofacial Radiology},
  year = {2024},
  doi = {10.1093/dmfr/twae024}
}
Kostenlos starten →