Discordant High-Sensitivity Cardiac Troponin I Concentrations in the General Population

Peter A Kavsak, Jinhui Ma

Clinical Chemistry · 02.03.2024 · 70 (3) · 562-564

DOI: 10.1093/clinchem/hvad224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Chemistry, online erschienen am 01.02.2024. Verfasst von Peter A Kavsak und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON, Canada. Hauptthemen laut MEDLINE: Troponin I, Troponin T. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 5 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For high-sensitivity cardiac troponin (hs-cTn) assays, analytical errors and discordant results may occur, with recent publications providing an approach for investigating such occurrences (1–3). Early in the laboratory investigation of these clinical queries, testing the specific sample(s) with an alternate hs-cTn assay is recommended, and for cardiac troponin I (cTnI) there are several high-sensitivity cardiac troponin I (hs-cTnI) assays that have undergone rigorous analytical validation and interference testing (2, 3). Importantly, a significant concentration discrepancy between different hs-cTnI assays has helped to provide some local estimates of interferences/discordant results in the hospital setting (2, 3). Unfortunately, little is known about the prevalence of analytically discordant hs-cTnI results in the general population. To estimate this, hs-cTnI data from the National Health and Nutrition Examination Survey (NHANES) with hs-cTnI concentrations from 3 different hs-cTnI assays was assessed (4). The NHANES data for hs-cTnI was obtained from participants (≥1 year of age) who consented for serum storage (1999 to 2004). The hs-cTnI concentrations were obtained from the Abbott ARCHITECT i2000SR, the Siemens Centaur XP, and the Ortho Vitros 3600 analyzers, with analytical performance previously published (4). There were 19 026 serum samples with a concentration reported from all 3 assays. For research purposes, hs-cTnI values were reported as low as 0 ng/L, below the limit of blank (LOB), which permitted analytical comparison and discordant investigations at the low end for all three assays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin ITroponin THumans

Substanzen

Troponin ITroponin T

Autor:innen und Institutionen

  • Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON, Canada.
  • Department of Health Research Methods, Evidence, and Impact, McMaster University, Hamilton, ON, Canada.

Zitieren

APA

Kavsak, P. A., & Ma, J. (2024). Discordant High-Sensitivity Cardiac Troponin I Concentrations in the General Population. Clinical Chemistry, 70(3), 562-564. https://doi.org/10.1093/clinchem/hvad224

Vancouver

Kavsak PA, Ma J. Discordant High-Sensitivity Cardiac Troponin I Concentrations in the General Population. Clinical Chemistry. 2024;70(3):562-564. doi:10.1093/clinchem/hvad224

BibTeX
@article{Kavsak2024,
  author = {Kavsak, Peter A and Ma, Jinhui},
  title = {Discordant High-Sensitivity Cardiac Troponin I Concentrations in the General Population},
  journal = {Clinical Chemistry},
  year = {2024},
  volume = {70},
  number = {3},
  pages = {562--564},
  doi = {10.1093/clinchem/hvad224}
}
Kostenlos starten →