EUVIMEDEUVIMED entdecken
Crossref

Recommendations for Setting a Criterion and Assessing Commutability of Sample Materials Used in External Quality Assessment/Proficiency Testing Schemes

Sverre Sandberg, Pernille Fauskanger, Jesper V Johansen, Thomas Keller iD, Jeffrey Budd, Neil Greenberg, Robert Rej iD, Mauro Panteghini, Vincent Delatour, Ferruccio Ceriotti iD, Liesbet Deprez, Johanna E Camara und 6 weitere

Clinical Chemistry · 02.11.2023 · 69 (11) · 1227-1237

DOI: 10.1093/clinchem/hvad135 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Chemistry, online erschienen am 19.09.2023. Verfasst von Sverre Sandberg und 17 weiteren Autor:innen. Beteiligte Einrichtung: Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway. Hauptthemen laut MEDLINE: Laboratory Proficiency Testing, Clinical Laboratory Services. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Laboratory Proficiency TestingClinical Laboratory ServicesHumansReference StandardsReagent Kits, Diagnostic

Substanzen

Reagent Kits, Diagnostic

Autor:innen und Institutionen

  • Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway.
  • Norwegian Porphyria Centre, Department of Medical Biochemistry and Pharmacology, Haukeland University Hospital, Bergen, Norway.
  • Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway.
  • Radiometer Medical ApS, Copenhagen, Denmark.
  • ACOMED statistic, Leipzig, Germany.
  • Jeff Budd Consulting, St. Paul, MN, United States.

ORCID-Profile: Thomas Keller, Robert Rej, Ferruccio Ceriotti, Alicia N Lyle

Zitieren

APA

Sandberg, S., Fauskanger, P., Johansen, J. V., Keller, T., Budd, J., Greenberg, N., Rej, R., Panteghini, M., Delatour, V., Ceriotti, F., Deprez, L., Camara, J. E., MacKenzie, F., Lyle, A. N., van der Hagen, E., Burns, C., Greg Miller, W., & IFCC Working Group on Commutability in Metrological Traceability (2023). Recommendations for Setting a Criterion and Assessing Commutability of Sample Materials Used in External Quality Assessment/Proficiency Testing Schemes. Clinical Chemistry, 69(11), 1227-1237. https://doi.org/10.1093/clinchem/hvad135

Vancouver

Sandberg S, Fauskanger P, Johansen JV, Keller T, Budd J, Greenberg N, et al. Recommendations for Setting a Criterion and Assessing Commutability of Sample Materials Used in External Quality Assessment/Proficiency Testing Schemes. Clinical Chemistry. 2023;69(11):1227-1237. doi:10.1093/clinchem/hvad135

BibTeX
@article{Sandberg2023,
  author = {Sandberg, Sverre and Fauskanger, Pernille and Johansen, Jesper V and Keller, Thomas and Budd, Jeffrey and Greenberg, Neil and Rej, Robert and Panteghini, Mauro and Delatour, Vincent and Ceriotti, Ferruccio and Deprez, Liesbet and Camara, Johanna E and MacKenzie, Finlay and Lyle, Alicia N and van der Hagen, Eline and Burns, Chris and Greg Miller, W and IFCC Working Group on Commutability in Metrological Traceability, IFCC Working Group on Commutability in Metrological Traceability},
  title = {Recommendations for Setting a Criterion and Assessing Commutability of Sample Materials Used in External Quality Assessment/Proficiency Testing Schemes},
  journal = {Clinical Chemistry},
  year = {2023},
  volume = {69},
  number = {11},
  pages = {1227--1237},
  doi = {10.1093/clinchem/hvad135}
}
Kostenlos starten →