Variability in Fetal Fraction Estimation: Comparing Fetal Fractions Reported by Noninvasive Prenatal Testing Providers Globally
Clinical Chemistry · 2023
DOI: 10.1093/clinchem/hvac207 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Chemistry, 2023. Verfasst von Ellis C Becking und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics, Division of Women and Baby, Wilhelmina Childrens Hospital, University Medical Center Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Noninvasive Prenatal Testing. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Fetal fraction (FF) measurement is considered important for reliable noninvasive prenatal testing (NIPT). Using minimal FF threshold as a quality parameter is under debate. We evaluated the variability in reported FFs of individual samples between providers and laboratories and within a single laboratory.
Methods
Genomic quality assessment and European Molecular Genetics Quality Network provide joint proficiency testing for NIPT. We compared reported FFs across all laboratories and stratified according to test methodologies. A single sample was sequenced repeatedly and FF estimated by 2 bioinformatics methods: Veriseq2 and SeqFF. Finally, we compared FFs by Veriseq and SeqFF in 87 351 NIPT samples.
Results
For each proficiency test sample we observed a large variability in reported FF, SDs and CVs ranging from 1.7 to 3.6 and 17.0 to 35.8, respectively. FF measurements reported by single nucleotide polymorphism-based methods had smaller SDs (0.5 to 2.4) compared to whole genome sequencing-based methods (1.8 to 2.9). In the internal quality assessment, SDs were similar between SeqFF (SD 1.0) and Veriseq v2 (SD 0.9), but mean FF by Veriseq v2 was higher compared to SeqFF (9.0 vs 6.4, P 0.001). In patient samples, reported FFs were on average 1.12-points higher in Veriseq than in SeqFF (P 0.001).
Conclusions
Current methods do not allow for a reliable and consistent FF estimation. Our data show estimated FF should be regarded as a laboratory-specific range, rather than a precise number. Applying strict universal minimum thresholds might result in unnecessary test failures and should be used with caution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Obstetrics, Division of Women and Baby, Wilhelmina Childrens Hospital, University Medical Center Utrecht, Utrecht, The Netherlands.
- Department of Human Genetics, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
- Amsterdam Reproduction and Development, Amsterdam, The Netherlands.
- Manchester Science Park, EMQN CIC, Manchester, UK.
- Genomics Quality Assessment, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, UK.
- North Thames Genomic Laboratory Hub, Great Ormond Street NHS Foundation Trust and Genetics and Genomics, UCL Great Ormond Street Institute of Child Health, London, UK.
ORCID-Profile: Ellis C Becking, Erik A Sistermans
Zitieren
APA
Becking, E. C., Linthorst, J., Patton, S., Gutowska-Ding, W., Goodall, R., Khawaja, F., Morgan, F., Deans, Z., Chitty, L. S., Bekker, M. N., Scheffer, P. G., & Sistermans, E. A. (2023). Variability in Fetal Fraction Estimation: Comparing Fetal Fractions Reported by Noninvasive Prenatal Testing Providers Globally. Clinical Chemistry. https://doi.org/10.1093/clinchem/hvac207
Vancouver
Becking EC, Linthorst J, Patton S, Gutowska-Ding W, Goodall R, Khawaja F, et al. Variability in Fetal Fraction Estimation: Comparing Fetal Fractions Reported by Noninvasive Prenatal Testing Providers Globally. Clinical Chemistry. 2023. doi:10.1093/clinchem/hvac207
BibTeX
@article{Becking2023,
author = {Becking, Ellis C and Linthorst, Jasper and Patton, Simon and Gutowska-Ding, Weronika and Goodall, Rebecca and Khawaja, Farrah and Morgan, Fiona and Deans, Zandra and Chitty, Lyn S and Bekker, Mireille N and Scheffer, Peter G and Sistermans, Erik A},
title = {Variability in Fetal Fraction Estimation: Comparing Fetal Fractions Reported by Noninvasive Prenatal Testing Providers Globally},
journal = {Clinical Chemistry},
year = {2023},
doi = {10.1093/clinchem/hvac207}
}
EUVIMED