Intradialytic hypotension is severely underreported by intermittent blood pressure readings
Clinical Kidney Journal · 02.01.2026 · 19 (1)
DOI: 10.1093/ckj/sfaf337 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Kidney Journal, online erschienen am 11.11.2025. Verfasst von Sabrine Chaara und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Niercentrum aan de Amstel.
Abstract (Originalsprache)
Background
Intradialytic hypotension (IDH) has been associated with both morbidity and mortality. Yet, as IDH often occurs asymptomatic, it might be easily missed with routine twice per hour brachial artery cuff-blood pressure (BAC-BP) readings. This study evaluated differences in IDH detection between intermittent BAC-BP and continuous BP monitoring with a finger cuff (FC-BP). Validation of the FC device was an additional objective.
Methods
In 40 chronic dialysis patients, intradialytic BP was measured during four sessions using (i) BAC-BP every 15 minutes and (ii) beat-to-beat FC-BP readings, which were averaged over 20-seconds intervals. IDH was defined as a systolic BP (SBP) <90 or <100 mmHg, depending on pre-dialysis SBP. Only FC measurements with an acceptable accuracy (i.e. mean SBP bias ≤10 mmHg) were used for the IDH analysis. For validation, sequential same-arm BP measurements were compared, using Bland–Altman analyses to assess agreement and four-quadrant plots to evaluate concordance.
Results
For IDH analysis, 144 BAC-BP readings and 18 163 FC-BP measurements were recorded in 106 hours. While BAC-BP identified 20 IDH episodes, 441 were detected by FC-BP. For validation, Bland–Altman analyses of 1221 paired BP readings showed a mean bias ± limits of agreement of −13.3 ± 44.5 mmHg for SBP and −13.3 ± 25.5 mmHg for diastolic BP. Only 27.7% of the paired FC-BP readings met the acceptable accuracy criterion. Concordance rates were 34.3% and 36.3%, respectively.
Conclusions
First, the occurrence of IDH is severely underestimated with intermittent BP monitoring. Second, FC-BP appears unsuitable for routine intradialytic BP monitoring due to its poor accuracy, precision, and concordance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, division of Nephrology, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
- Amsterdam Cardiovascular Sciences, Diabetes & Hypertensive Diseases, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
- Department of Internal Medicine, St. Antonius Hospital, Nieuwegein, the Netherlands.
- Department of Internal Medicine, Leiden University Medical Centre, Leiden, the Netherlands.
- Department of Internal Medicine, Gelre Hospitals, Apeldoorn, the Netherlands.
- Department of Internal Medicine, Spaarne Gasthuis, Haarlem, the Netherlands.
ORCID-Profile: Camiel L M de Roij van Zuijdewijn
Förderung
- Niercentrum aan de Amstel
Zitieren
APA
Chaara, S., Grooteman, M. P. C., Nubé, M. J., Bos, W. J. W., Rootjes, P. A., Wijngaarden, G., & de Roij van Zuijdewijn, C. L. M. (2026). Intradialytic hypotension is severely underreported by intermittent blood pressure readings. Clinical Kidney Journal, 19(1). https://doi.org/10.1093/ckj/sfaf337
Vancouver
Chaara S, Grooteman MPC, Nubé MJ, Bos WJW, Rootjes PA, Wijngaarden G, et al. Intradialytic hypotension is severely underreported by intermittent blood pressure readings. Clinical Kidney Journal. 2026;19(1). doi:10.1093/ckj/sfaf337
BibTeX
@article{Chaara2026,
author = {Chaara, Sabrine and Grooteman, Muriel P C and Nubé, Menso J and Bos, Willem Jan W and Rootjes, Paul A and Wijngaarden, Gertrude and de Roij van Zuijdewijn, Camiel L M},
title = {Intradialytic hypotension is severely underreported by intermittent blood pressure readings},
journal = {Clinical Kidney Journal},
year = {2026},
volume = {19},
number = {1},
doi = {10.1093/ckj/sfaf337}
}