EUVIMEDEUVIMED entdecken
QuerschnittstudieOpen Access · CC BY 4.0

Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study

Han Thi Nguyen iD, Luan Nguyen Quang Vo iD, Andrew James Codlin, Rachel Forse, Tom Wingfield iD, Kristi Sidney Annerstedt, Emily Lai-Ho MacLean iD, Jacob Creswell iD, Beatrice Kirubi, Hoa Binh Nguyen iD, Luong Van Dinh, Ha Thu Doan und 2 weitere

Clinical Infectious Diseases · 2025

DOI: 10.1093/cid/ciaf561 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Clinical Infectious Diseases, 2025. Verfasst von Han Thi Nguyen und 13 weiteren Autor:innen. Beteiligte Einrichtung: Research Department, FIT RD Social Enterprise Company Limited (FIT RD), Hanoi, Vietnam. Hauptthemen laut MEDLINE: Tuberculosis, Tuberculosis, Pulmonary. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Tuberculosis (TB) infection is a driver of the global TB epidemic. Accurate, affordable, and simpler diagnostics are crucial for identifying people for preventive therapy. We evaluated the diagnostic performance of the STANDARD F TB-Feron FIA (TB-Feron), a near-point-of-care (POC) assay for detecting TB infection.

Methods

From June to December 2024, we conducted a cross-sectional study at the Vietnam National Lung Hospital, enrolling 352 participants, including 345 eligible participants: 95 with microbiologically confirmed pulmonary TB (Group 1), 200 household contacts of people with pulmonary TB (Group 2), and 50 with a recent history of a negative QFT-Plus result and no known TB exposure (Group 3). Participants were tested with TB-Feron and the reference standard, QuantiFERON TB Gold Plus (QFT-Plus). Results were compared for sensitivity and specificity (primary endpoints), with inter-test agreement (Cohen's κ) and reproducibility (Bland–Altman analysis) as secondary outcomes.

Results

Among 345 eligible participants, TB-Feron sensitivity was 88.4% (95% confidence interval [CI] 80.2–94.1) in Group 1, and specificity was 70.0% (55.4–82.1) in Group 3. In Group 2, positive and negative agreements with QFT-Plus were 89.2% (79.8–95.2%) and 75.4% (66.9–82.6), respectively, with inter-test agreement of 80.5% (Cohen's κ=0.6069, P < .0001). Intra-test reproducibility showed no significant differences in IFN-γ levels (mean difference = 2.08 IU/mL, 95% CI −1.28 to 5.44, P = .206).

Conclusions

With high sensitivity, the TB-Feron assay is a potential near-POC alternative to the QFT-Plus assay for diagnosing TB infection, but requires consideration of its suboptimal specificity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TuberculosisTuberculosis, PulmonaryHumansCross-Sectional StudiesVietnamMaleFemaleAdultSensitivity and SpecificityMiddle AgedReproducibility of ResultsInterferon-gamma Release TestsYoung AdultAdolescentAgedMycobacterium tuberculosisPoint-of-Care Testing

Stichwörter der Autor:innen

QuantiFERON-TB Gold PlusTBfluorescent immunoassayinterferon-gamma release assayspoint of care

Autor:innen und Institutionen

  • Research Department, FIT RD Social Enterprise Company Limited (FIT RD), Hanoi, Vietnam.
  • Division of Infectious Diseases, Department of Medicine, Karolinska Institutet, Stockholm, Sweden.
  • Management, Friends for International TB Relief, Hanoi, Vietnam.
  • Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden.
  • Centre for Tuberculosis Research, Departments of Clinical Sciences and International Public Health, Liverpool School of Tropical Medicine, Liverpool, United Kingdom.
  • Tropical and Infectious Diseases Unit, Liverpool University Hospitals NHS Foundation Trust, Liverpool, United Kingdom.

ORCID-Profile: Han Thi Nguyen, Luan Nguyen Quang Vo, Tom Wingfield, Emily Lai-Ho MacLean, Jacob Creswell, Hoa Binh Nguyen

Zitieren

APA

Nguyen, H. T., Vo, L. N. Q., Codlin, A. J., Forse, R., Wingfield, T., Annerstedt, K. S., MacLean, E. L., Creswell, J., Kirubi, B., Nguyen, H. B., Van Dinh, L., Doan, H. T., Forsman, L. D., & TBI Testing Team (2025). Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study. Clinical Infectious Diseases. https://doi.org/10.1093/cid/ciaf561

Vancouver

Nguyen HT, Vo LNQ, Codlin AJ, Forse R, Wingfield T, Annerstedt KS, et al. Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study. Clinical Infectious Diseases. 2025. doi:10.1093/cid/ciaf561

BibTeX
@article{Nguyen2025,
  author = {Nguyen, Han Thi and Vo, Luan Nguyen Quang and Codlin, Andrew James and Forse, Rachel and Wingfield, Tom and Annerstedt, Kristi Sidney and MacLean, Emily Lai-Ho and Creswell, Jacob and Kirubi, Beatrice and Nguyen, Hoa Binh and Van Dinh, Luong and Doan, Ha Thu and Forsman, Lina Davies and TBI Testing Team, TBI Testing Team},
  title = {Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study},
  journal = {Clinical Infectious Diseases},
  year = {2025},
  doi = {10.1093/cid/ciaf561}
}
Kostenlos starten →