EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseVergleichsstudie

Contamination of Blood Cultures Drawn From Arterial Catheters Versus Venipuncture or Venous Catheters in Critically Ill Patients: A Systematic Review and Meta-analysis

Takatoshi Koroki iD, Motoki Fujii iD, Yuki Kotani iD, Takahiko Yaguchi, Taisuke Shibata iD, Chihiro Hirata, Naoki Okawa iD, Koshi Ota iD, Mayuko Tonai iD, Toshiyuki Karumai iD, Yuki Kataoka iD, Yoshiro Hayashi iD

Clinical Infectious Diseases · 17.03.2026 · 82 (3) · 446-452

DOI: 10.1093/cid/ciaf260 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Clinical Infectious Diseases, online erschienen am 20.05.2025. Verfasst von Takatoshi Koroki und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intensive Care Medicine, Kameda Medical Center, Kamogawa, Chiba, Japan. Hauptthemen laut MEDLINE: Blood Culture, Phlebotomy, Equipment Contamination, Blood Specimen Collection. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Arterial catheter–drawn blood culture sampling may reduce patient discomfort and healthcare providers' workload. Guidelines discourage transcatheter blood culture collection due to contamination risks, mainly derived from data on venous catheter–drawn cultures. However, contamination rates of arterial catheter–drawn cultures have not been comprehensively evaluated compared with venipuncture- or venous catheter–drawn cultures.

Methods

We searched PubMed, Embase, and the Cochrane Library from inception through 5 December 2023, for studies comparing arterial catheter–drawn blood cultures with venipuncture- or venous catheter–drawn blood cultures. The primary outcome was blood culture contamination rate. We performed a random-effects meta-analysis and evaluated the certainty of the evidence using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) methodology.

Results

We included 6 studies involving 8533 blood cultures. When comparing arterial catheter– with venipuncture-drawn cultures, the crude contamination rates were 28/1355 (2.1%) and 103/4539 (2.3%), respectively. Arterial catheter–drawn cultures may not increase contamination rates compared to venipuncture-drawn cultures (risk difference [RD], 0.01 [95% confidence interval {CI}, −.01 to .02]; low certainty). When comparing arterial catheter– with venous catheter–drawn cultures, the crude contamination rates were 15/489 (3.1%) and 211/2639 (8.0%), respectively. Compared to venous catheter–drawn cultures, arterial catheter–drawn cultures may have lower contamination rates (RD, −0.05 [95% CI, −.11 to .01]; low certainty).

Conclusions

In critically ill patients, arterial catheter–drawn blood cultures may have contamination rates comparable to venipuncture-drawn cultures and potentially lower than venous catheter–drawn cultures. Clinical Trials Registration PROSPERO (CRD42023486227).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood CulturePhlebotomyEquipment ContaminationBlood Specimen CollectionCatheterization, PeripheralHumansCritical Illness

Stichwörter der Autor:innen

arterial lineblood culturecontaminationcritical caresystematic review

Autor:innen und Institutionen

  • Department of Intensive Care Medicine, Kameda Medical Center, Kamogawa, Chiba, Japan.
  • Department of Infectious Diseases, Kameda Medical Center, Kamogawa, Chiba, Japan.
  • Department of Emergency and Critical Care Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
  • Department of Internal Medicine, Kyoto Min-Iren Asukai Hospital, Sakyo-ku, Kyoto, Japan.
  • Department of Systematic Reviewers, Scientific Research Works Peer Support Group, Osaka, Osaka, Japan.
  • Department of Healthcare Epidemiology, Kyoto University Graduate School of Medicine, School of Public Health, Sakyo-ku, Kyoto, Japan.

ORCID-Profile: Takatoshi Koroki, Motoki Fujii, Yuki Kotani, Taisuke Shibata, Naoki Okawa, Koshi Ota, Mayuko Tonai, Toshiyuki Karumai, Yuki Kataoka, Yoshiro Hayashi

Zitieren

APA

Koroki, T., Fujii, M., Kotani, Y., Yaguchi, T., Shibata, T., Hirata, C., Okawa, N., Ota, K., Tonai, M., Karumai, T., Kataoka, Y., & Hayashi, Y. (2026). Contamination of Blood Cultures Drawn From Arterial Catheters Versus Venipuncture or Venous Catheters in Critically Ill Patients: A Systematic Review and Meta-analysis. Clinical Infectious Diseases, 82(3), 446-452. https://doi.org/10.1093/cid/ciaf260

Vancouver

Koroki T, Fujii M, Kotani Y, Yaguchi T, Shibata T, Hirata C, et al. Contamination of Blood Cultures Drawn From Arterial Catheters Versus Venipuncture or Venous Catheters in Critically Ill Patients: A Systematic Review and Meta-analysis. Clinical Infectious Diseases. 2026;82(3):446-452. doi:10.1093/cid/ciaf260

BibTeX
@article{Koroki2026,
  author = {Koroki, Takatoshi and Fujii, Motoki and Kotani, Yuki and Yaguchi, Takahiko and Shibata, Taisuke and Hirata, Chihiro and Okawa, Naoki and Ota, Koshi and Tonai, Mayuko and Karumai, Toshiyuki and Kataoka, Yuki and Hayashi, Yoshiro},
  title = {Contamination of Blood Cultures Drawn From Arterial Catheters Versus Venipuncture or Venous Catheters in Critically Ill Patients: A Systematic Review and Meta-analysis},
  journal = {Clinical Infectious Diseases},
  year = {2026},
  volume = {82},
  number = {3},
  pages = {446--452},
  doi = {10.1093/cid/ciaf260}
}
Kostenlos starten →