EUVIMEDEUVIMED entdecken
Open Access

Use of Statistical Process Control Methods for Early Detection of Healthcare Facility–Associated Nontuberculous Mycobacteria Outbreaks: A Single-Center Pilot Study

Arthur W Baker iD, Ahmed Maged, Salah Haridy, Jason E Stout, Jessica L Seidelman, Sarah S Lewis, Deverick J Anderson

Clinical Infectious Diseases · 2023

DOI: 10.1093/cid/ciac923 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Infectious Diseases, 2023. Verfasst von Arthur W Baker und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Infectious Diseases, Duke University School of Medicine, Durham, North Carolina, USA. Hauptthemen laut MEDLINE: Mycobacterium Infections, Nontuberculous, Mycobacterium abscessus, Cross Infection. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, NIH HHS, National Institute of Allergy and Infectious Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Nontuberculous mycobacteria (NTM) are emerging pathogens increasingly implicated in healthcare facility–associated (HCFA) infections and outbreaks. We analyzed the performance of statistical process control (SPC) methods in detecting HCFA NTM outbreaks.

Methods

We retrospectively analyzed 3 NTM outbreaks that occurred from 2013 to 2016 at a tertiary care hospital. The outbreaks consisted of pulmonary Mycobacterium abscessus complex (MABC) acquisition, cardiac surgery–associated extrapulmonary MABC infection, and a bronchoscopy-associated pseudo-outbreak of Mycobacterium avium complex (MAC). We analyzed monthly case rates of unique patients who had positive respiratory cultures for MABC, non-respiratory cultures for MABC, and bronchoalveolar lavage cultures for MAC, respectively. For each outbreak, we used these rates to construct a pilot moving average (MA) SPC chart with a rolling baseline window. We also explored the performance of numerous alternative control charts, including exponentially weighted MA, Shewhart, and cumulative sum charts.

Results

The pilot MA chart detected each outbreak within 2 months of outbreak onset, preceding actual outbreak detection by an average of 6 months. Over a combined 117 months of pre-outbreak and post-outbreak surveillance, no false-positive SPC signals occurred (specificity, 100%). Prospective use of this chart for NTM surveillance could have prevented an estimated 108 cases of NTM. Six high-performing alternative charts detected all outbreaks during the month of onset, with specificities ranging from 85.7% to 94.9%.

Conclusions

SPC methods have potential to substantially improve HCFA NTM surveillance, promoting early outbreak detection and prevention of NTM infections. Additional study is needed to determine the best application of SPC for prospective HCFA NTM surveillance in other settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mycobacterium Infections, NontuberculousMycobacterium abscessusCross InfectionHumansNontuberculous MycobacteriaPilot ProjectsRetrospective StudiesMycobacterium avium ComplexDisease OutbreaksDelivery of Health Care

Stichwörter der Autor:innen

hospital outbreakinfection preventionnontuberculous mycobacteriastatistical process control

Autor:innen und Institutionen

  • Division of Infectious Diseases, Duke University School of Medicine, Durham, North Carolina, USA.
  • Duke Center for Antimicrobial Stewardship and Infection Prevention, Durham, North Carolina, USA.
  • Department of Advanced Design and Systems Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China.
  • Department of Mechanical Engineering, Benha University, Benha, Egypt.
  • Department of Industrial Engineering and Engineering Management, College of Engineering, University of Sharjah, Sharjah, United Arab Emirates.
  • Benha Faculty of Engineering, Benha University, Benha, Egypt.

ORCID-Profile: Arthur W Baker

Förderung

  • NIAID NIH HHS
  • NIH HHS
  • National Institute of Allergy and Infectious Diseases
  • National Institutes of Health

Zitieren

APA

Baker, A. W., Maged, A., Haridy, S., Stout, J. E., Seidelman, J. L., Lewis, S. S., & Anderson, D. J. (2023). Use of Statistical Process Control Methods for Early Detection of Healthcare Facility–Associated Nontuberculous Mycobacteria Outbreaks: A Single-Center Pilot Study. Clinical Infectious Diseases. https://doi.org/10.1093/cid/ciac923

Vancouver

Baker AW, Maged A, Haridy S, Stout JE, Seidelman JL, Lewis SS, et al. Use of Statistical Process Control Methods for Early Detection of Healthcare Facility–Associated Nontuberculous Mycobacteria Outbreaks: A Single-Center Pilot Study. Clinical Infectious Diseases. 2023. doi:10.1093/cid/ciac923

BibTeX
@article{Baker2023,
  author = {Baker, Arthur W and Maged, Ahmed and Haridy, Salah and Stout, Jason E and Seidelman, Jessica L and Lewis, Sarah S and Anderson, Deverick J},
  title = {Use of Statistical Process Control Methods for Early Detection of Healthcare Facility–Associated Nontuberculous Mycobacteria Outbreaks: A Single-Center Pilot Study},
  journal = {Clinical Infectious Diseases},
  year = {2023},
  doi = {10.1093/cid/ciac923}
}
Kostenlos starten →