EUVIMEDEUVIMED entdecken
Crossref

Eco-friendly stability-indicating chromatographic methods with integrated molecular docking and ADMET evaluation for simultaneous determination of carvedilol and ivabradine

Haitham A El Fiky, Maha F Abd El Ghany, Amr M Badawey, Nermine V Fares, Dina A Ahmed

Journal of Chromatographic Science · 2026

DOI: 10.1093/chromsci/bmag028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatographic Science, 2026. Verfasst von Haitham A El Fiky und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutical Chemistry Department, Faculty of Pharmacy, Future University in Egypt, End of 90th St., Fifth Settlement, New Cairo 11835, Egypt. Hauptthemen laut MEDLINE: Carvedilol, Ivabradine, Molecular Docking Simulation. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, many researchers strive to create eco-conscious methods for drug separation to avoid hazardous solvents. In line with this objective, this study focuses on developing two green chromatographic methods, TLC and UPLC, to determine the mixture of carvedilol (CAR) and ivabradine (IVA) used for controlling stable angina symptoms, along with their oxidative degradates. The TLC method employed toluene: methanol: ammonia (8:2:0.2, by volume) as a mobile phase and silica gel plates as the stationary phase, with detection at 270.0 nm using concentration ranges of 0.5-8.0 μg/band for each drug. The optimized UPLC method utilized a mobile phase of ethanol: 0.1% triethylamine adjusted by acetic acid to pH 6.4 (40:60 v/v) on an Agilent Poroshell C18 (150 mm × 3 mm) column, with a 0.3 mL/min flow rate at 30°C and fluorimetric detection at 285.0 nm excitation and 330.0 nm emission, with linearity of 0.2-12.0 μg/mL for both drugs. Green assessment of the proposed methods with 82 and 78 green Eco-scores, AGREE score values of 0.77 and 0.72 for UPLC and TLC methods, respectively were performed. Moreover, statistical comparison of the proposed methods with reported and official methods was conducted. Additionally, structure elucidation, molecular docking and ADMET assessment of the degradates were successfully performed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarvedilolIvabradineMolecular Docking SimulationChromatography, High Pressure LiquidDrug StabilityReproducibility of ResultsLimit of DetectionChromatography, Thin LayerGreen Chemistry TechnologyLinear Models

Substanzen

CarvedilolIvabradine

Autor:innen und Institutionen

  • Pharmaceutical Chemistry Department, Faculty of Pharmacy, Future University in Egypt, End of 90th St., Fifth Settlement, New Cairo 11835, Egypt.
  • Analytical Chemistry Department, Faculty of Pharmacy, Ain shams University, Abbasiya, Cairo 11566, Egypt.
  • Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini St, Cairo 11562, Egypt.

Zitieren

APA

El Fiky, H. A., Abd El Ghany, M. F., Badawey, A. M., Fares, N. V., & Ahmed, D. A. (2026). Eco-friendly stability-indicating chromatographic methods with integrated molecular docking and ADMET evaluation for simultaneous determination of carvedilol and ivabradine. Journal of Chromatographic Science. https://doi.org/10.1093/chromsci/bmag028

Vancouver

El Fiky HA, Abd El Ghany MF, Badawey AM, Fares NV, Ahmed DA. Eco-friendly stability-indicating chromatographic methods with integrated molecular docking and ADMET evaluation for simultaneous determination of carvedilol and ivabradine. Journal of Chromatographic Science. 2026. doi:10.1093/chromsci/bmag028

BibTeX
@article{ElFiky2026,
  author = {El Fiky, Haitham A and Abd El Ghany, Maha F and Badawey, Amr M and Fares, Nermine V and Ahmed, Dina A},
  title = {Eco-friendly stability-indicating chromatographic methods with integrated molecular docking and ADMET evaluation for simultaneous determination of carvedilol and ivabradine},
  journal = {Journal of Chromatographic Science},
  year = {2026},
  doi = {10.1093/chromsci/bmag028}
}
Kostenlos starten →