A simple method for the determination of Atrazine in lake water by gas chromatography with electron capture detector (GC-ECD) using dispersive liquid–liquid microextraction (DLLME)
Journal of Chromatographic Science · 30.04.2026 · 64 (5)
DOI: 10.1093/chromsci/bmag018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatographic Science, online erschienen am 28.05.2026. Verfasst von Angélica de Fátima Bortolato Piccioli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Programa de Pós-graduação em Engenharia de Energia na Agricultura (PPGEA), Universidade Estadual do Oeste do Paraná (UNIOESTE), Rua Universitária, n°…. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Coordination of Superior Level Staff Improvement (CAPES), National Council for Scientific and Technological Development.
Abstract (Originalsprache)
Atrazine (ATZ) is a persistent herbicide found in aquatic environments worldwide, and the evaluation and monitoring of potential contamination by this pesticide are of utmost importance. A properly validated and well-established analytical method is important to detect ATZ in the environment. In this work, a dispersive liquid–liquid microsyringe extraction method was developed for the pre-concentration of ATZ in lake water samples for subsequent determination in a gas chromatograph with an electron capture detection (GC-ECD) system. The method showed excellent linearity in the range of 2 μg L−1 to 30 μg L−1, with correlation coefficient (R) values ≥0.995. In addition, the method is selective, and the sample matrix does not interfere with the determinations (≤20%). The limits of detection and limits of quantification were 0.6 μg L−1 and 2 μg L−1, respectively. The method is accurate, with recoveries ranging from 100% to 114%, and precise (13%). The extraction method associated with GC-ECD is reliable, sensitive, simple, fast, reproducible, environmentally friendly and economical. The method was applied to water samples from the Municipal Lake of the city of Cascavel (PR, Brazil) and no ATZ was detected in any of the samples.
Autor:innen und Institutionen
- Programa de Pós-graduação em Engenharia de Energia na Agricultura (PPGEA), Universidade Estadual do Oeste do Paraná (UNIOESTE), Rua Universitária, n° 2069, Jardim Universitário, Cascavel, Paraná - CEP 85819-110, Brazil.
- Programa de Pós-graduação em Conservação e Manejo de Recursos Naturais (PPRN), Universidade Estadual do Oeste do Paraná (UNIOESTE), Rua Universitária, n° 2069, Jardim Universitário, Cascavel, Paraná - CEP 85819-110, Bra…
ORCID-Profile: Angélica de Fátima Bortolato Piccioli
Förderung
- Coordination of Superior Level Staff Improvement (CAPES)
- National Council for Scientific and Technological Development
Zitieren
APA
Piccioli, A. F. B., Gonçalves, A. C., Carraro, B. P., & Zanini, E. S. (2026). A simple method for the determination of Atrazine in lake water by gas chromatography with electron capture detector (GC-ECD) using dispersive liquid–liquid microextraction (DLLME). Journal of Chromatographic Science, 64(5). https://doi.org/10.1093/chromsci/bmag018
Vancouver
Piccioli AFB, Gonçalves AC, Carraro BP, Zanini ES. A simple method for the determination of Atrazine in lake water by gas chromatography with electron capture detector (GC-ECD) using dispersive liquid–liquid microextraction (DLLME). Journal of Chromatographic Science. 2026;64(5). doi:10.1093/chromsci/bmag018
BibTeX
@article{Piccioli2026,
author = {Piccioli, Angélica de Fátima Bortolato and Gonçalves, Affonso Celso and Carraro, Bianca Pierina and Zanini, Emanuel Sobocinsk},
title = {A simple method for the determination of Atrazine in lake water by gas chromatography with electron capture detector (GC-ECD) using dispersive liquid–liquid microextraction (DLLME)},
journal = {Journal of Chromatographic Science},
year = {2026},
volume = {64},
number = {5},
doi = {10.1093/chromsci/bmag018}
}
EUVIMED