A Sensitive Liquid Chromatography-Mass Spectrometric Method for Determination of Bisoprolol in Rat Serum after Pre-Column Derivatization
Journal of Chromatographic Science · 2023
DOI: 10.1093/chromsci/bmad056 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatographic Science, 2023. Verfasst von Huda A Shaheen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia. Hauptthemen laut MEDLINE: Bisoprolol, Limit of Detection. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Deanship of Scientific Research, King Abdulaziz University.
Abstract (Originalsprache)
Two derivatization regents were reacted with bisoprolol (BIS), followed by liquid-chromatography-mass spectrometric analysis. 3-Bromomethyl-propyphenazone (BMP) and dansyl-chloride (Dns-Cl) were reacted via the secondary amino group using a catalyst to accelerate the reaction progress and completeness with minimal reaction byproducts. The sensitivity and the ionization efficiency of both BIS-methyl-propyphenazone (BIS-MP) and BIS-Dns via electrospray ionization were studied. The sensitivity of BIS-MP was superior to BIS-Dns. The derivatization procedure, extraction procedure, and LC-MS method were optimized and validated to achieve the monitoring of BIS in rat serum at a picogram scale. The calibration curve showed a regression coefficient value of 0.999 within a concentration spanning a range of 10–500 pg/mL. The detection limit and quantitation were 4 and 10 pg/mL, respectively. The intraday and inter-day precision values (% relative standard deviation) ranged from 0.53 to 6.91%, whereas the accuracy values (expressed as % error) ranged from −4.20 to −0.77%. The pharmacokinetic parameters were: 15,280 pg/mL for a maximum concentration of BIS (Cmax) at the maximum time (Tmax) of 1 h. BIS’s elimination half-life (t1/2) was determined to be 3 h. The value of the area under the concentration-time curve (AUC0 − t) was 34,370 pg/mL h.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
ORCID-Profile: Huda A Shaheen
Förderung
- Deanship of Scientific Research
- King Abdulaziz University
Zitieren
APA
Shaheen, H. A., Bahaffi, S. O., & Khedr, A. M. (2023). A Sensitive Liquid Chromatography-Mass Spectrometric Method for Determination of Bisoprolol in Rat Serum after Pre-Column Derivatization. Journal of Chromatographic Science. https://doi.org/10.1093/chromsci/bmad056
Vancouver
Shaheen HA, Bahaffi SO, Khedr AM. A Sensitive Liquid Chromatography-Mass Spectrometric Method for Determination of Bisoprolol in Rat Serum after Pre-Column Derivatization. Journal of Chromatographic Science. 2023. doi:10.1093/chromsci/bmad056
BibTeX
@article{Shaheen2023,
author = {Shaheen, Huda A and Bahaffi, Saleh O and Khedr, Alaa M},
title = {A Sensitive Liquid Chromatography-Mass Spectrometric Method for Determination of Bisoprolol in Rat Serum after Pre-Column Derivatization},
journal = {Journal of Chromatographic Science},
year = {2023},
doi = {10.1093/chromsci/bmad056}
}