EUVIMEDEUVIMED entdecken
Crossref

Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS)

Md Tauquir Alam, Md Ali Mujtaba, Afzal Hussain, Abuzer Ali, Mohd Imran, Md Abul Barkat iD, Sherif A Abdel-Gawad

Journal of Chromatographic Science · 2023

DOI: 10.1093/chromsci/bmac054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatographic Science, 2023. Verfasst von Md Tauquir Alam und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Northern Border University, Rafha 91911, Saudi Arabia. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Taif University Researchers Supporting Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A biosensitive analysis method development and validation was performed for accurate and rapid quantification of cefdinir (CDR) in human plasma by a liquid chromatography–tandem mass spectrometry technique coupled with electrospray ionization. Analysis was carried out using a C18 column with a flow rate of 1.0 mL/min and operating temperature of 30.0 ± 1°C. The drug was eluted by optimizing the m/z ratios of 396.20 → 227.20 and 428.17 → 241.10, for cefdinir and IS (internal standard), respectively. The intraday precision (%CV) for Cefdinir ranged from 2.8% and 6.7% as lower limit of quantification of quality control (LLOQ QC) and higher level of quantification of quality control (HQC QC), respectively, whereas these value were found to be as 3.0% and 5.6% for LLOQ and HQC, respectively after interday precision. Moreover, accuracy ranged from 107.70% (HQC QC) to 95.5% (LLOQ QC). The extraction mean recovery was found to be 83.91 ± 6.0% for cefdinir and 76.7 ± 6.23% for IS. The drug was stable throughout the analysis period. It was possible to analyze several plasma samples every day since each sample took <2.5 min to run. The method demonstrated successful quantification of CDR in human plasma, followed by pharmacokinetic profiles that were simple, accurate, sensitive and cost-effective.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometrySpectrometry, Mass, Electrospray IonizationHumansChromatography, LiquidCefdinirChromatography, High Pressure LiquidSolid Phase ExtractionReproducibility of Results

Substanzen

Cefdinir

Autor:innen und Institutionen

  • Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Northern Border University, Rafha 91911, Saudi Arabia.
  • Department of Pharmaceutics, Faculty of Pharmacy, Northern Border University, Rafha 91911, Saudi Arabia.
  • Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
  • Department of Pharmacognosy, College of Pharmacy, Taif University, P. O. Box 11099, Taif 21944, Saudi Arabia.
  • Department of Pharmaceutics, College of Pharmacy, University of Hafr Al-Batin, Al Jamiah, Hafr Al Batin 39524, Saudi Arabia.
  • Pharmaceutical Chemistry Department, College of Pharmacy, Prince Sattam Bin Abdulaziz University, Al Kharj 11942, Saudi Arabia.

ORCID-Profile: Md Abul Barkat

Förderung

  • Taif University Researchers Supporting Project

Zitieren

APA

Alam, M. T., Mujtaba, M. A., Hussain, A., Ali, A., Imran, M., Barkat, M. A., & Abdel-Gawad, S. A. (2023). Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS). Journal of Chromatographic Science. https://doi.org/10.1093/chromsci/bmac054

Vancouver

Alam MT, Mujtaba MA, Hussain A, Ali A, Imran M, Barkat MA, et al. Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS). Journal of Chromatographic Science. 2023. doi:10.1093/chromsci/bmac054

BibTeX
@article{Alam2023,
  author = {Alam, Md Tauquir and Mujtaba, Md Ali and Hussain, Afzal and Ali, Abuzer and Imran, Mohd and Barkat, Md Abul and Abdel-Gawad, Sherif A},
  title = {Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS)},
  journal = {Journal of Chromatographic Science},
  year = {2023},
  doi = {10.1093/chromsci/bmac054}
}
Kostenlos starten →