A new method for automated olfactory threshold testing
Chemical Senses · 2025
DOI: 10.1093/chemse/bjaf029 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Chemical Senses, 2025. Verfasst von Veikko Surakka und 12 weiteren Autor:innen. Beteiligte Einrichtung: Research Group for Emotions, Sociality, and Computing, Faculty of Information Technology and Communication Sciences, Tampere University, Tampere, Fin…. Hauptthemen laut MEDLINE: Sensory Thresholds, Olfactory Perception, Self-Testing, Neuropsychological Tests. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Academy of Finland, Tampere University, Technical University Dresden.
Abstract (Originalsprache)
We present a new method for fully self-administered olfactory testing. Technical development and testing and 2 user studies were conducted to test the functionality of a prototype device called Automated Olfactory Threshold Test (AutomOT). Technical testing showed repeatable functioning of the developed olfactory display technology in accurately producing 11 predefined odor intensity levels over 10 different days. In User Study 1, we tested the reliability, usability, and subjective workload of the use of the device. Participants (N = 29) with a normal sense of smell performed an automated threshold test 4 times. The results showed that the correlations between the tests were statistically significant, r = 0.44 to 0.78, all P-values ≤0.018. In User Study 2, we demonstrated the functioning of the device with normosmic and hyposmic/anosmic participants (n = 23 and n = 27, respectively) who performed both the current clinical standard, Sniffin’ Sticks test, and the AutomOT test. Also, the usability and subjective workload of the use of the device were evaluated. The overall correlation of olfactory thresholds between the Sniffin’ Sticks and the AutomOT was r = 0.48, P < 0.001. In both user studies, the results indicated good usability as measured by the System Usability Scale and low workload assessed by NASA Task Load Index. Overall, the results suggest that the newly developed AutomOT test is a reliable, valid, and usable tool for clinical assessment of olfactory thresholds.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Group for Emotions, Sociality, and Computing, Faculty of Information Technology and Communication Sciences, Tampere University, Tampere, Finland.
- Micro- and Nanosystems Research Group, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
- Sensor Technology and Biomeasurements, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
- Department of Otorhinolaryngology, Smell and Taste Clinic, Technical University Dresden, Dresden, Germany.
ORCID-Profile: Veikko Surakka, Marko Björkbacka, Jani Lylykangas, Jussi Rantala, Timo Salpavaara, Jarmo Verho, Oleg Spakov, Venla Kamppari, Philipp Müller, Antti Vehkaoja, Pasi Kallio, Divesh Thaploo, Thomas Hummel
Förderung
- Academy of Finland
- Tampere University
- Technical University Dresden
- Volkswagenstiftung
Zitieren
APA
Surakka, V., Björkbacka, M., Lylykangas, J., Rantala, J., Salpavaara, T., Verho, J., Spakov, O., Kamppari, V., Müller, P., Vehkaoja, A., Kallio, P., Thaploo, D., & Hummel, T. (2025). A new method for automated olfactory threshold testing. Chemical Senses. https://doi.org/10.1093/chemse/bjaf029
Vancouver
Surakka V, Björkbacka M, Lylykangas J, Rantala J, Salpavaara T, Verho J, et al. A new method for automated olfactory threshold testing. Chemical Senses. 2025. doi:10.1093/chemse/bjaf029
BibTeX
@article{Surakka2025,
author = {Surakka, Veikko and Björkbacka, Marko and Lylykangas, Jani and Rantala, Jussi and Salpavaara, Timo and Verho, Jarmo and Spakov, Oleg and Kamppari, Venla and Müller, Philipp and Vehkaoja, Antti and Kallio, Pasi and Thaploo, Divesh and Hummel, Thomas},
title = {A new method for automated olfactory threshold testing},
journal = {Chemical Senses},
year = {2025},
doi = {10.1093/chemse/bjaf029}
}
EUVIMED