EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Long-term reliability and stability of parameterized resting state EEG: evidence from a five-year follow-up

Polina Politanskaia, Jacinta Bywater, Anna J Finley, Hannah A D Keage, Nicholas J Kelley, Daniel J McKeown iD, Victor R Schinazi, Douglas J Angus iD

Cerebral Cortex · 14.07.2026 · 36 (7)

DOI: 10.1093/cercor/bhag113 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cerebral Cortex, online erschienen am 10.08.2026. Verfasst von Polina Politanskaia und 7 weiteren Autor:innen. Beteiligte Einrichtung: Bond University, Gold Coast, Queensland, Australia. Hauptthemen laut MEDLINE: Electroencephalography, Aging, Rest, Brain. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Bond University Postgraduate Research Scholarship, National Research Foundation Singapore, Campus for Research Excellence and Technological Enterprise.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Several aspects of parameterized neural activity, including the aperiodic exponent and individual peak alpha frequency, have emerged as promising biomarkers for ageing, pathology, and cognitive decline. Their potential clinical application is tempered by a lack of evidence on long-term temporal stability. Existing investigations have largely relied on cross-sectional designs or considered stability for up to 90 days. Here, we examined five-year reliability, stability, and age-associated changes in periodic and aperiodic neural activity using electroencephalography in adults aged 20-70 years. Resting-state EEG was recorded in two sessions, approximately five years apart. We extracted the aperiodic exponent, aperiodic offset, peak alpha power, and individual alpha peak frequency and examined test-retest reliability at both the channel and cluster levels. All parameters demonstrated fair to excellent test-retest reliability (intraclass correlations = 0.51-0.88). Linear mixed models revealed that individual peak alpha frequency decreased, the aperiodic exponent flattened, and parameterized alpha power remained unchanged. There were no interactions between time and age. Our findings suggest that parameterized activity is reliable over long timeframes, and demonstrates changes consistent with ageing-related processes. Spectral parameterization may provide a means of characterizing within-person neurophysiological changes across adulthood. Future research should explore the utility of identifying deviations that may indicate pathology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyAgingRestBrainHumansReproducibility of ResultsAdultFemaleAgedMiddle AgedMaleYoung AdultAlpha RhythmFollow-Up Studies

Stichwörter der Autor:innen

EEGageingalphaaperiodicreliability

Autor:innen und Institutionen

  • Bond University, Gold Coast, Queensland, Australia.
  • North Dakota State University, Fargo, North Dakota, United States of America.
  • Adelaide University, Adelaide, South Australia, Australia.
  • University of Southampton, Southampton, United Kingdom.

ORCID-Profile: Daniel J McKeown, Douglas J Angus

Förderung

  • Bond University Postgraduate Research Scholarship
  • National Research Foundation Singapore
  • Campus for Research Excellence and Technological Enterprise

Zitieren

APA

Politanskaia, P., Bywater, J., Finley, A. J., Keage, H. A. D., Kelley, N. J., McKeown, D. J., Schinazi, V. R., & Angus, D. J. (2026). Long-term reliability and stability of parameterized resting state EEG: evidence from a five-year follow-up. Cerebral Cortex, 36(7). https://doi.org/10.1093/cercor/bhag113

Vancouver

Politanskaia P, Bywater J, Finley AJ, Keage HAD, Kelley NJ, McKeown DJ, et al. Long-term reliability and stability of parameterized resting state EEG: evidence from a five-year follow-up. Cerebral Cortex. 2026;36(7). doi:10.1093/cercor/bhag113

BibTeX
@article{Politanskaia2026,
  author = {Politanskaia, Polina and Bywater, Jacinta and Finley, Anna J and Keage, Hannah A D and Kelley, Nicholas J and McKeown, Daniel J and Schinazi, Victor R and Angus, Douglas J},
  title = {Long-term reliability and stability of parameterized resting state EEG: evidence from a five-year follow-up},
  journal = {Cerebral Cortex},
  year = {2026},
  volume = {36},
  number = {7},
  doi = {10.1093/cercor/bhag113}
}
Kostenlos starten →