Comprehensive flow cytometry-based diagnosis of XIAP deficiency
Clinical and Experimental Immunology · 2025
DOI: 10.1093/cei/uxaf020 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Experimental Immunology, 2025. Verfasst von Dan Tomomasa und 28 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics and Developmental Biology, Institute of Science Tokyo, Tokyo, Japan. Hauptthemen laut MEDLINE: Flow Cytometry, X-Linked Inhibitor of Apoptosis Protein, Lymphohistiocytosis, Hemophagocytic, Genetic Diseases, X-Linked. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Deficiency of X-linked inhibitor of apoptosis protein (XIAP) is an X-linked recessive inborn error of immunity characterized by abnormal immune responses leading to inflammatory bowel disease and hemophagocytic lymphohistiocytosis. Although XIAP protein expression analysis by flow cytometry (XIAP flow) is commonly used to diagnose XIAP deficiency, certain variants may not affect the protein expression, thereby complicating the diagnostic process. XIAP is crucial for the nucleotide-binding and oligomerization domain 2 (NOD2) signaling pathway. In this study, we aimed to perform a comprehensive analysis of nine patients diagnosed with XIAP deficiency through genetic testing. In addition to XIAP flow, we employed a previously reported method utilizing muramyl dipeptide (MDP) stimulation, a specific agonist of NOD2, to quantitatively evaluate the downstream tumor necrosis factor-alpha (TNFα) production by flow cytometry in patient monocytes (MDP flow). The median mean fluorescence intensity in healthy controls with XIAP flow was 711 (95% confidence interval [CI], 653–815) compared to 195 (95% CI, 161–386) in patients with XIAP deficiency (P < 0.0001). The median percentage of TNFα-producing monocytes in controls with MDP flow was 29.1% (95% CI, 19.6–53.7), while in patients it was 0.34% (95% CI, 0.18–0.82) (P = 0.0008). The receiver operating characteristic curves demonstrated that both XIAP flow and MDP flow exhibited 100% sensitivity and specificity. Taken together, combining XIAP flow and MDP flow analyses allows for a highly accurate diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pediatrics and Developmental Biology, Institute of Science Tokyo, Tokyo, Japan.
- Department of Pediatrics, Graduate School of Medical Sciences Kumamoto University, Kumamoto, Japan.
- Royal College of Surgeons in Ireland, Dublin, Ireland.
- Laboratory of Lymphocyte Activation and Susceptibility to EBV infection, INSERM UMR 1163, Imagine Institute, Paris, France.
- Department of Child Health and Development, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.
- Clinical Research Center, Institute of Science Tokyo Hospital, Tokyo, Japan.
ORCID-Profile: Masaki Shimizu, Atsushi Hijikata, Satoshi Okada, Tomohiro Morio, Hirokazu Kanegane
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Tomomasa, D., Nishimura, M., Ohya, A., Tanita, K., Wakatsuki, R., Watanabe, R., Miyamoto, S., Hoshino, A., Kamiya, T., Isoda, T., Kaneko, S., Shimizu, M., Hijikata, A., Eguchi, K., Ishimura, M., Maeda, Y., Izawa, K., Meguro, T., Fujimoto, K., …, & Kanegane, H. (2025). Comprehensive flow cytometry-based diagnosis of XIAP deficiency. Clinical and Experimental Immunology. https://doi.org/10.1093/cei/uxaf020
Vancouver
Tomomasa D, Nishimura M, Ohya A, Tanita K, Wakatsuki R, Watanabe R, et al. Comprehensive flow cytometry-based diagnosis of XIAP deficiency. Clinical and Experimental Immunology. 2025. doi:10.1093/cei/uxaf020
BibTeX
@article{Tomomasa2025,
author = {Tomomasa, Dan and Nishimura, Madoka and Ohya, Ayami and Tanita, Kay and Wakatsuki, Ryosuke and Watanabe, Ryohei and Miyamoto, Satoshi and Hoshino, Akihiro and Kamiya, Takahiro and Isoda, Takeshi and Kaneko, Shuya and Shimizu, Masaki and Hijikata, Atsushi and Eguchi, Katsuhide and Ishimura, Masataka and Maeda, Yukako and Izawa, Kazushi and Meguro, Takaaki and Fujimoto, Kosuke and Ishikita-Murayama, Etsuko and Suzuki, Kyogo and Okura, Eri and Uehara, Tomoko and Takayama, Tomotada and Okada, Satoshi and Takagi, Masatoshi and Morio, Tomohiro and Marsh, Rebecca A and Kanegane, Hirokazu},
title = {Comprehensive flow cytometry-based diagnosis of XIAP deficiency},
journal = {Clinical and Experimental Immunology},
year = {2025},
doi = {10.1093/cei/uxaf020}
}
EUVIMED