Post-combustion CCUS retrofits for existing coal-fired power plants: from capture rate to credible net CO2 avoidance
Clean Energy · 11.11.2026
DOI: 10.1093/ce/zkag081 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clean Energy, online erschienen am 11.11.2026. Verfasst von Dipankar Paul. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Existing coal-fired power plants remain large sources of carbon dioxide, but some units will continue to supply firm and flexible electricity during the energy transition. They can lower their emissions with carbon capture, utilization and post-combustion storage. But a high capture rate in itself does not demonstrate deep decarbonization. The outcome is determined by the extraction of steam, auxiliary electricity consumption, extra fuel usage, compression, part-load operation, capture availability, transportation reliability and the fate of the CO2 at the end. This special structured review critically assesses established sources and asks when a retrofit can realistically achieve credible net CO2 abatement per net electricity unit. The analysis employs one sequential pathway of decision. In the first, net-avoidance accounting reconciles the baseline and full-chain boundary. Second, an evidence-maturity ladder confines every assertion by its supporting data. Third, a retrofit-readiness matrix for host-plant and downstream compatibility. Solvent capture is the most strongly field evident. For the Taizhou project, it recorded a 90.86% capture, 99.94% product purity, 2.35 GJ/tCO2 thermal demand, 51.5 kWh/tCO2 electrical demand and over 400 running days. KoSol had more than 10,000 hours of operation across the regeneration energy window of 2.17-2.34 GJ/tCO2. While emerging sorbent, membrane, heat-pump and looping systems improve selected metrics, most evidence is pilot- or model-based. The worked calcium-looping example showed positive modeled operational CO2 avoidance. Full-chain net CO2 avoidance remained indeterminate, and the available evidence did not support site-specific deployment. Thus, harmonized net-MWh accounting, use of robust operating evidence, and a verifiable downstream sink are prerequisites for credible retrofit decisions.
Zitieren
APA
Paul, D. (2026). Post-combustion CCUS retrofits for existing coal-fired power plants: from capture rate to credible net CO2 avoidance. Clean Energy. https://doi.org/10.1093/ce/zkag081
Vancouver
Paul D. Post-combustion CCUS retrofits for existing coal-fired power plants: from capture rate to credible net CO2 avoidance. Clean Energy. 2026. doi:10.1093/ce/zkag081
BibTeX
@article{Paul2026,
author = {Paul, Dipankar},
title = {Post-combustion CCUS retrofits for existing coal-fired power plants: from capture rate to credible net CO2 avoidance},
journal = {Clean Energy},
year = {2026},
doi = {10.1093/ce/zkag081}
}
EUVIMED