Indirect electrochemical detection of creatinine in human urine samples using a bare boron-doped diamond electrode
Bulletin of the Chemical Society of Japan · 03.07.2025 · 98 (7)
DOI: 10.1093/bulcsj/uoaf069 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bulletin of the Chemical Society of Japan, online erschienen am 16.07.2025. Verfasst von Ziping Zhang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Scientific Research A, Scientific Research B, Takeda Science Foundation.
Abstract (Originalsprache)
Electrochemical sensors have been recognized as a promising candidate in point-of-care testing, which is due to their sensitivity, time-saving, low cost, and portability. This work aims to develop a simple and sustainable electrochemical method to measure creatinine (CRE) in real urine. While the present electrochemical sensors for CRE detection rely on the modified electrodes for sensing CRE, our work simply used a bare boron-doped diamond (BDD) electrode without any modification to detect CRE in the urine samples. This method consists of a continuous electrochemical redox reaction of CRE with the addition of NaNO2 in the neutral solution. By using this method, CRE in the range of 0.0377 mg/dL (3.3 μM) to 200 mg/dL (17.68 mM) exhibits linear performance on the BDD electrode. The results are in good agreement with the Jaffé method obtained from the typical spectrophotometric analysis. This strategy has the potential to detect urinary CRE, which could be clinically valuable.
Förderung
- Scientific Research A
- Scientific Research B
- Takeda Science Foundation
- Mochida Memorial Foundation
- Medical and Pharmaceutical Research
- The Naito Foundation
Zitieren
APA
Zhang, Z., Ogata, G., & Einaga, Y. (2025). Indirect electrochemical detection of creatinine in human urine samples using a bare boron-doped diamond electrode. Bulletin of the Chemical Society of Japan, 98(7). https://doi.org/10.1093/bulcsj/uoaf069
Vancouver
Zhang Z, Ogata G, Einaga Y. Indirect electrochemical detection of creatinine in human urine samples using a bare boron-doped diamond electrode. Bulletin of the Chemical Society of Japan. 2025;98(7). doi:10.1093/bulcsj/uoaf069
BibTeX
@article{Zhang2025,
author = {Zhang, Ziping and Ogata, Genki and Einaga, Yasuaki},
title = {Indirect electrochemical detection of creatinine in human urine samples using a bare boron-doped diamond electrode},
journal = {Bulletin of the Chemical Society of Japan},
year = {2025},
volume = {98},
number = {7},
doi = {10.1093/bulcsj/uoaf069}
}
EUVIMED