Supercritical carbon dioxide fluid extraction and trace ICP-MS determination of speciation, preconcentration transport, and recovery of vanadium with 2, 8, 14, 20-tetramethyl-11, 23-dinitro calix[4]resorcinarene-5, 17-dihydroxamic acid after microwave-assisted digestion
Bulletin of the Chemical Society of Japan · 30.04.2025 · 98 (5)
DOI: 10.1093/bulcsj/uoaf037 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bulletin of the Chemical Society of Japan, online erschienen am 15.05.2025. Verfasst von Bignesh Thakur und 3 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
In a supercritical carbon dioxide (SF-CO2)-n-octanol medium, vanadium (V) is extracted, preconcentrated, and speciated with 2, 8, 14, 20-tetramethyl-11, 23-dinitro calix[4]resorcinarene-5, 17-dihydroxamic acid, and NMC4RADHA. By using spectrophotometry and inductively coupled plasma-mass spectrophotometry (ICP-MS), the vanadium(V)-NMC4RADHA complex in n-octanol was measured. The NMC4RADHA complex and 1:1 VO2 are produced by the extracted species in SF-CO2 extraction (SFE). Vanadium is measured at the nanogram-to-milligram level when a number of cations and anions are present. The impact of temperature, pressure, modifier concentration, and diluents on vanadium extraction and separation was investigated. The technique is used to measure the amount of vanadium in ambient, seawater, and actual reference samples after the National Bureau of Standards and other microwave digested samples. Vanadium (V) can be transported selectively and effectively by using the NMC4RADHA as a carrier. The maximum transportation of vanadium was recorded for 12 min, with t1/2 equal to 6.3 min. Vanadium (V) was measured when vanadium (IV) was present. With a maximum absorbance of 546 nm, there was a molar absorptivity of 1.8 × 104 L mol−1 cm−1, a recovery of 98.40%, and a Beer's Law compliance of 0.25–2.83 mg/L Limit of Detection (LoD) 0.132 mg/mL LoD. ICP-MS measurements of LoD 0.0099 mg/mL and LoD 0.030 mg mL−1 were used to inject the extract. The vanadium was also separated and recovered through the membrane. Standard alloys and dietary, environmental, and biological materials are tested for vanadium.
Zitieren
APA
Thakur, B., Pandya, N., Shukla, V., & Agrawal, Y. (2025). Supercritical carbon dioxide fluid extraction and trace ICP-MS determination of speciation, preconcentration transport, and recovery of vanadium with 2, 8, 14, 20-tetramethyl-11, 23-dinitro calix[4]resorcinarene-5, 17-dihydroxamic acid after microwave-assisted digestion. Bulletin of the Chemical Society of Japan, 98(5). https://doi.org/10.1093/bulcsj/uoaf037
Vancouver
Thakur B, Pandya N, Shukla V, Agrawal Y. Supercritical carbon dioxide fluid extraction and trace ICP-MS determination of speciation, preconcentration transport, and recovery of vanadium with 2, 8, 14, 20-tetramethyl-11, 23-dinitro calix[4]resorcinarene-5, 17-dihydroxamic acid after microwave-assisted digestion. Bulletin of the Chemical Society of Japan. 2025;98(5). doi:10.1093/bulcsj/uoaf037
BibTeX
@article{Thakur2025,
author = {Thakur, Bignesh and Pandya, Nirav and Shukla, Viral and Agrawal, Yadvendra},
title = {Supercritical carbon dioxide fluid extraction and trace ICP-MS determination of speciation, preconcentration transport, and recovery of vanadium with 2, 8, 14, 20-tetramethyl-11, 23-dinitro calix[4]resorcinarene-5, 17-dihydroxamic acid after microwave-assisted digestion},
journal = {Bulletin of the Chemical Society of Japan},
year = {2025},
volume = {98},
number = {5},
doi = {10.1093/bulcsj/uoaf037}
}
EUVIMED