EUVIMEDEUVIMED entdecken
Crossref

TPTh 7.11 Robotic Distal Pancreatectomy with the Versius Robotic Surgical System: Our Experience

Samikkumar Brandyopadhyay, Natasha Chafuwa, Ajith Siriwardena, Saurabh Jamdar, Santhalingam Jegadeeswaran

British Journal of Surgery · 05.08.2026 · 113 (Supplement_8)

DOI: 10.1093/bjs/znag087.500 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 05.08.2026. Verfasst von Samikkumar Brandyopadhyay und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Distal pancreatectomy is a well established minimally invasive procedure. However, the feasibility and technical nuances of utilising the Versius robotic surgical system remains unexplored. Methodology A retrospective analysis was conducted on all consecutive robotic distal pancreatectomies performed at a reputable Infirmary Hospital in England. These included both distal pancreatectomy with splenectomy and spleen preserving distal pancreatectomy.

Results

Between May 2021 and January 2025, a total of fifteen robotic distal pancreatotomies were performed, comprising eleven distal pancreatectomies with splenectomy and four spleen preserving distal pancreatectomies. The procedures were primarily conducted by two hepato-pancreato-biliary surgeons, employing four robotic arms and one assistant port. The instrumentation predominantly included two graspers, a monopolar hook and bipolar forceps. Conversion to open surgery occurred in one case. The mean operating time was two hundred and seventeen minutes (range: one hundred and eighteen to three hundred and twenty minutes), with an average robot docking time of eight point one minutes (range: three to fifteen minutes). Complications were observed in four cases (twenty seven percent), including clinically relevant postoperative pancreatic fistula in four patients (twenty seven percent). One patient was reoperated for rebleeding and no ninety-day mortality was recorded.

Conclusion

The use of the Versius robotic surgical system for robotic distal pancreatectomies is both safe and feasible, with early cases requiring careful patient selection.

Zitieren

APA

Brandyopadhyay, S., Chafuwa, N., Siriwardena, A., Jamdar, S., & Jegadeeswaran, S. (2026). TPTh 7.11 Robotic Distal Pancreatectomy with the Versius Robotic Surgical System: Our Experience. British Journal of Surgery, 113(Supplement_8). https://doi.org/10.1093/bjs/znag087.500

Vancouver

Brandyopadhyay S, Chafuwa N, Siriwardena A, Jamdar S, Jegadeeswaran S. TPTh 7.11 Robotic Distal Pancreatectomy with the Versius Robotic Surgical System: Our Experience. British Journal of Surgery. 2026;113(Supplement_8). doi:10.1093/bjs/znag087.500

BibTeX
@article{Brandyopadhyay2026,
  author = {Brandyopadhyay, Samikkumar and Chafuwa, Natasha and Siriwardena, Ajith and Jamdar, Saurabh and Jegadeeswaran, Santhalingam},
  title = {TPTh 7.11 Robotic Distal Pancreatectomy with the Versius Robotic Surgical System: Our Experience},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_8},
  doi = {10.1093/bjs/znag087.500}
}
Kostenlos starten →