Aim
To evaluate the diagnostic performance of Technetium-99m sestamibi (MIBI) scintigraphy and CT scan in the localisation of parathyroid disease.
Methods
A retrospective analysis of 128 consecutive patients who parathyroid surgery at a single centre was performed. Imaging data were extracted and cross-checked by two clinicians independently. Image finding was referenced to the histological outcomes.
Results
78.1% were female with mean age of 62.9 years. MIBI was performed in 85.9% of patients. Overall, 48.4%(n=62) underwent both MIBI and additional (metachronous) CT scan of the neck; of these 48.3% had a negative MIBI scan. Among negative MIBI scan, 53.3% turned out to be CT-positive. Overall agreement between CT and MIBI was 59.6%. When compared with histology, the sensitivity of MIBI alone was 66.7% (95% CI 57.3–75.0), with side-correct localisation (right vs left) of 59.8% (95% CI 49.8–69.1). In subgroup analysis, MIBI with synchronous SPECT-CT did not significantly improve side localisation (64.1%, 95% CI 48.4–77.3) compared without SPECT-CT (55.9%, 95% CI 44.1–67.1). However, synchronous SPECT-CT with MIBI scan improved exact gland localisation (side and quadrant): 57.9% (95% CI 42.2–72.1) versus 36.9% (95% CI 26.2–49.1). Finally,22.6% of patients in whom both CT and MIBI were negative pre-operatively, only 7.1% were true negatives on histology despite extensive surgical exploration.
Conclusion
MIBI scanning demonstrates reasonable diagnostic performance but does not exclude parathyroid disease when negative. Additional CT neck imaging provides a valuable rescue strategy, while SPECT-CT improves precise gland localisation but not side determination.
Zitieren
APA
Mojarad, S., Hobby, E., Middlemass, L., Li, D. C., & Akhtar, I. (2026). TPW 8.10 Finding the Parathyroid gland: Easier Said Than Scanned. British Journal of Surgery, 113(Supplement_8). https://doi.org/10.1093/bjs/znag087.398
Vancouver
Mojarad S, Hobby E, Middlemass L, Li DC, Akhtar I. TPW 8.10 Finding the Parathyroid gland: Easier Said Than Scanned. British Journal of Surgery. 2026;113(Supplement_8). doi:10.1093/bjs/znag087.398
BibTeX
@article{Mojarad2026,
author = {Mojarad, Sanam and Hobby, Eleanor and Middlemass, Layla and Li, David Chunhei and Akhtar, Irfan},
title = {TPW 8.10 Finding the Parathyroid gland: Easier Said Than Scanned},
journal = {British Journal of Surgery},
year = {2026},
volume = {113},
number = {Supplement_8},
doi = {10.1093/bjs/znag087.398}
}
EUVIMED