EUVIMEDEUVIMED entdecken
Crossref

TPT 5.10 Introduction of Shaped Mesh for Laparoscopic Inguinal Hernia Repair to Reduce Traumatic Fixation

Mary Claxton, Blazej Rybinski, Lewasha RaviArul, Marianne Hollyman

British Journal of Surgery · 05.08.2026 · 113 (Supplement_8)

DOI: 10.1093/bjs/znag087.222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 05.08.2026. Verfasst von Mary Claxton und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To assess whether introducing shaped mesh influences fixation practices in laparoscopic inguinal hernia repair at a district general hospital, with a secondary evaluation of cost implications.

Methods

Two cohorts were compared at a single UK centre. A retrospective group included 46 consecutive repairs (January–April 2025). Following a departmental teaching session on shaped mesh, non-traumatic fixation, and equipment costs, a trial was introduced. A prospective cohort of 37 repairs (May–November 2025) was then collected. Data included demographics, operative approach (TAPP/TEPP), mesh type, fixation method, and peritoneal closure. All cases were performed by consultants or supervised trainees. Procurement data showed shaped mesh cost £167.76 versus £27.72 for standard mesh; fixation devices cost £241–£254.

Results

Shaped mesh use increased from 18% to 43%, with a corresponding reduction in standard mesh (82% to 57%). Glue fixation was eliminated (20% to 0%), and fixation-free repairs doubled (11% to 22%). Despite this, overall traumatic fixation rates remained unchanged (67% vs 70%). TEPP use doubled (9% to 19%). V-lock suturing became the preferred peritoneal closure method (33% to 43%), reducing tacker use (35% to 27%). Average costs increased from £241.05 to £270.14 for unilateral repairs and £369.16 to £397.91 for bilateral repairs.

Conclusions

Educational intervention increased shaped mesh adoption and encouraged more no-fixation repairs. However, traumatic fixation rates did not fall, indicating shaped mesh alone does not shift fixation behaviour. Increased shaped mesh use alongside ongoing fixation device use has raised overall procedural costs, requiring departmental review.

Zitieren

APA

Claxton, M., Rybinski, B., RaviArul, L., & Hollyman, M. (2026). TPT 5.10 Introduction of Shaped Mesh for Laparoscopic Inguinal Hernia Repair to Reduce Traumatic Fixation. British Journal of Surgery, 113(Supplement_8). https://doi.org/10.1093/bjs/znag087.222

Vancouver

Claxton M, Rybinski B, RaviArul L, Hollyman M. TPT 5.10 Introduction of Shaped Mesh for Laparoscopic Inguinal Hernia Repair to Reduce Traumatic Fixation. British Journal of Surgery. 2026;113(Supplement_8). doi:10.1093/bjs/znag087.222

BibTeX
@article{Claxton2026,
  author = {Claxton, Mary and Rybinski, Blazej and RaviArul, Lewasha and Hollyman, Marianne},
  title = {TPT 5.10 Introduction of Shaped Mesh for Laparoscopic Inguinal Hernia Repair to Reduce Traumatic Fixation},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_8},
  doi = {10.1093/bjs/znag087.222}
}
Kostenlos starten →