Abstract (Originalsprache)

Background

Wire-guided localisation is the standard technique for excision of non-palpable breast lesions during breast-conserving surgery (BCS). For larger or more extensive lesions, multiple-wire (bracketing) localisation is often used, but its impact on surgical outcomes compared with single-wire localisation remains unclear.

Aim

To compare surgical outcomes associated with single-wire versus multiple-wire localisation in breast-conserving surgery.

Methods

A systematic review and meta-analysis was conducted in accordance with PRISMA guidelines. MEDLINE, EMBASE, PubMed, and the Cochrane Library were searched up to December 2025 for comparative observational studies evaluating single-wire versus multiple-wire localisation in adult patients undergoing BCS for breast cancer. Primary outcomes were re-excision and positive margin rates. Secondary outcomes included successful BCS and specimen volume. Meta-analysis was performed using Review Manager 5.4 with random-effects models.

Results

Eight studies were included. Multiple-wire localisation was associated with a significantly lower risk of re-excision compared with single-wire localisation (RR 0.65, 95% CI 0.47–0.92, P = 0.01). There were no statistically significant differences in positive margin rates (RR 0.76, 95% CI 0.42–1.37, P = 0.36) or successful breast-conserving surgery (OR 1.77, 95% CI 0.64–4.88, P = 0.27). Multiple-wire localisation was associated with larger specimen volumes (SMD −0.42 favouring single-wire, 95% CI −0.68 to −0.16, P = 0.002).

Conclusion

Multiple-wire localisation in breast-conserving surgery is associated with lower re-excision rates and results in larger specimen volumes compared with single-wire localisation, with no clear difference in margin positivity or successful breast conservation.

Zitieren

APA

El-Tahlawy, Y., Saleem, Y., Mamum, M. A., Mahmood, W. U., Lubbad, O., & Sajid, M. S. (2026). TPT 4.08 Single-Wire Versus Multiple-Wire Localisation for Non-Palpable Breast Lesions in Breast-Conserving Surgery: A Systematic Review and Meta-Analysis. British Journal of Surgery, 113(Supplement_8). https://doi.org/10.1093/bjs/znag087.208

Vancouver

El-Tahlawy Y, Saleem Y, Mamum MA, Mahmood WU, Lubbad O, Sajid MS. TPT 4.08 Single-Wire Versus Multiple-Wire Localisation for Non-Palpable Breast Lesions in Breast-Conserving Surgery: A Systematic Review and Meta-Analysis. British Journal of Surgery. 2026;113(Supplement_8). doi:10.1093/bjs/znag087.208

BibTeX
@article{ElTahlawy2026,
  author = {El-Tahlawy, Yahya and Saleem, Yumna and Mamum, Mohammad Abir and Mahmood, Wajeeh Ullah and Lubbad, Omar and Sajid, Muhammad S},
  title = {TPT 4.08 Single-Wire Versus Multiple-Wire Localisation for Non-Palpable Breast Lesions in Breast-Conserving Surgery: A Systematic Review and Meta-Analysis},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_8},
  doi = {10.1093/bjs/znag087.208}
}
Kostenlos starten →