EUVIMEDEUVIMED entdecken
Crossref

1000 Improving Ureteric Stent Follow-Up: A Retrospective Audit of Delayed and Retained Stents in a District General Hospital

A M Chowdhury, A Parkhouse, N Lodhia, R David, F New

British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)

DOI: 10.1093/bjs/znag063.758 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von A M Chowdhury und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To evaluate documentation, follow-up planning and timeliness of ureteric stent removal in a district general hospital without an electronic stent-tracking system, and to quantify delayed or retained stents to support adoption of a registry.

Method

A retrospective review of all ureteric stents inserted between 1 March 2024 and 30 April 2025 was performed. Operation notes, discharge summaries and clinic letters were examined for removal plans and final outcomes. Long-term stents were excluded. Stents were classified as Not Delayed (≤6 weeks or by target), Delayed (>6 weeks without justification), Possible Retained (in situ at audit close), or Not Known (status unclear). Complications and device-related patterns were recorded.

Results

Ninety-three short-term stents were analysed. A documented removal plan appeared in 95.7% of cases and in 93.5% of discharge summaries. Timely removal occurred in 59.1%. Delayed removal occurred in 35.5% (33/93), including 4.3% that had remained in situ for more than six months. A further 3.2% had no evidence of removal at audit close (possible retained), and 2.1% could not be classified due to incomplete documentation. In 88% of delayed cases, no reason was recorded. The Cook UFI-600-R accounted for nearly half of insertions but 73% of delays and 93% of encrustations. The overall complication rate was 22.6%, predominantly encrustation.

Conclusions

Most delays lacked a recorded reason, and the Cook UFI-600-R accounted for the majority of prolonged dwell times and encrustations. These findings demonstrate significant gaps in follow-up processes and support the introduction of an electronic stent-tracking registry together with review of device choice.

Zitieren

APA

Chowdhury, A. M., Parkhouse, A., Lodhia, N., David, R., & New, F. (2026). 1000 Improving Ureteric Stent Follow-Up: A Retrospective Audit of Delayed and Retained Stents in a District General Hospital. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.758

Vancouver

Chowdhury AM, Parkhouse A, Lodhia N, David R, New F. 1000 Improving Ureteric Stent Follow-Up: A Retrospective Audit of Delayed and Retained Stents in a District General Hospital. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.758

BibTeX
@article{Chowdhury2026,
  author = {Chowdhury, A M and Parkhouse, A and Lodhia, N and David, R and New, F},
  title = {1000 Improving Ureteric Stent Follow-Up: A Retrospective Audit of Delayed and Retained Stents in a District General Hospital},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.758}
}
Kostenlos starten →