EUVIMEDEUVIMED entdecken
Crossref

467 Estimating Efficacy of Laser Systems for Retrograde Intrarenal and Ureteric Lithotripsy of Solitary Ureteric and Renal Calculi, Utilizing Stone Volume Measurements and Laser Safety Records

M Rahim, O Nasir, M Alabi, K Biswas, N Jayasooriya, S Keoghane, Z Maan, S Datta

British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)

DOI: 10.1093/bjs/znag063.744 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von M Rahim und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Predicting laser time and energy use during lithotripsy can support decision-making regarding operative duration, complication risk, and theatre planning. However, relationships between laser time, energy expenditure, and stone removal remain unclear. This audit investigates correlation between stone volume/density and laser performance metrics using the Lumenis Slimline Fibre 200 Ho:YAG system.

Method

Data on patients undergoing retrograde ureteric or renal endoscopy in a high-throughput stone unit were included. Exclusions were multiple, or staghorn stones. Laser time and energy use were extracted from laser safety records. Stone volume and density were calculated from preoperative CT-KUB scans using the ellipsoid formula, and postoperative imaging estimated the volume removed. Linear regression was used to analyse relationships between stone volume/density, laser time, and energy use.

Results

Sixty-one patients met inclusion criteria. Mean stone density was 1015 HU (312.6–1955.9) and mean volume 253.15 mm³ (22.04–1848.67). A statistically significant but weak relationship was found between laser time and the volume removed (R²=0.076, p=0.0317), indicating an average removal rate of 4.19 mm³/min (95% CI: 0.39–8.00). A stronger, significant relationship existed between energy use and volume removed (R²=0.426, p<0.001), with mean energy expenditure of 11.2 J/mm³ (95% CI: 0.0078–0.0146).

Conclusions

This retrospective review provides a simple, reproducible method for estimating operative metrics using routinely available stone data. The Lumenis Slimline Fibre 200 system removed ∼4.19 mm³/min and uses ∼11.2 J/mm³. These data may support comparison with other laser systems and improve case triage and theatre scheduling.

Zitieren

APA

Rahim, M., Nasir, O., Alabi, M., Biswas, K., Jayasooriya, N., Keoghane, S., Maan, Z., & Datta, S. (2026). 467 Estimating Efficacy of Laser Systems for Retrograde Intrarenal and Ureteric Lithotripsy of Solitary Ureteric and Renal Calculi, Utilizing Stone Volume Measurements and Laser Safety Records. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.744

Vancouver

Rahim M, Nasir O, Alabi M, Biswas K, Jayasooriya N, Keoghane S, et al. 467 Estimating Efficacy of Laser Systems for Retrograde Intrarenal and Ureteric Lithotripsy of Solitary Ureteric and Renal Calculi, Utilizing Stone Volume Measurements and Laser Safety Records. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.744

BibTeX
@article{Rahim2026,
  author = {Rahim, M and Nasir, O and Alabi, M and Biswas, K and Jayasooriya, N and Keoghane, S and Maan, Z and Datta, S},
  title = {467 Estimating Efficacy of Laser Systems for Retrograde Intrarenal and Ureteric Lithotripsy of Solitary Ureteric and Renal Calculi, Utilizing Stone Volume Measurements and Laser Safety Records},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.744}
}
Kostenlos starten →