737 Fascia Iliaca Block in the Emergency Department: Are We Meeting Safety Standards?
British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)
DOI: 10.1093/bjs/znag063.715 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von S Jaiswal.
Abstract (Originalsprache)
Aim
To evaluate the proportion of patients with neck of femur (NOF) fractures receiving a Fascia Iliaca Block (FIB) in the Emergency Department, and to assess the quality of documentation and monitoring against national regional anesthesia safety standards.
Method
A retrospective audit was conducted using patient records of individuals presenting to A&E with NOF fractures. Data collected included: documentation of consent, technique used, local anesthetic (LA) name, concentration, volume and dose, operator details, supervision, and monitoring at baseline, 10, 20 and 30 minutes post-procedure. Audit standards were derived from GPAS 2024, RA-UK and NatSSIPs guidance. Thirty cases were reviewed, and data were analyzed using Excel.
Results
Only 73% (22/30) of patients likely received an FIB based on available documentation. Of the 22 patients with a recorded FIB, 68% had consent documented. A total of 78% received an ultrasound-guided block. All cases recorded LA name and timing, but only 27% documented the injection site, and LA dose/concentration details were inconsistently recorded. All operators were documented; however, 60% required senior supervision, indicating limited independent competency. Monitoring compliance was poor: <50% had baseline observations or 10-minute post-block checks documented, and only ∼20% had 20- or 30-minute monitoring recorded.
Conclusions
Significant gaps were identified in FIB documentation and monitoring, raising patient safety concerns related to LA toxicity and procedural oversight. Improved adherence to regional anesthesia standards is required. Introduction of a structured FIB proforma, enhanced staff education, competency assessment, and re-audit are recommended to ensure safer, more consistent practice.
Zitieren
APA
Jaiswal, S. (2026). 737 Fascia Iliaca Block in the Emergency Department: Are We Meeting Safety Standards?. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.715
Vancouver
Jaiswal S. 737 Fascia Iliaca Block in the Emergency Department: Are We Meeting Safety Standards?. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.715
BibTeX
@article{Jaiswal2026,
author = {Jaiswal, S},
title = {737 Fascia Iliaca Block in the Emergency Department: Are We Meeting Safety Standards?},
journal = {British Journal of Surgery},
year = {2026},
volume = {113},
number = {Supplement_6},
doi = {10.1093/bjs/znag063.715}
}
EUVIMED