EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

447 Bolt-Connected External Ventricular Drain Versus Tunnelled External Ventricular Drain: A Systematic Review and Meta-Analysis Comparing Accuracy and Complications

I Abbas, T Ansari, M Lau, D Sivanesan, G Brown, W Cook, A Lisitsyna, M Kingham, Y Chedid, M Veremu, Y Karepov, E Viaroli und 3 weitere

British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)

DOI: 10.1093/bjs/znag063.673 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von I Abbas und 14 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

External ventricular drain (EVD) insertion is common in neurosurgery. Tunnelled catheters are secured subcutaneously to reduce complications, whereas bolt EVDs are fixed directly to the skull. This systematic review and meta-analysis compared complication profiles between the two approaches.

Method

A PRISMA-compliant systematic review and meta-analysis was conducted. Articles published in MEDLINE, Embase, and Cochrane Library between inception and 1 May 2025 were included. Reported outcomes included infection, revision, obstruction, catheter pullout, haemorrhage, and placement accuracy. Random effects meta-analysis models were utilised for pooled analyses.

Results

Of 254 articles, 15 studies were included (2797 patients; 1614 bolt EVD, 1183 tunnelled EVD). Infection rates were 13.8% (N=90/652) in the bolt group and 12.6% (N=139/1107) in the tunnelled group. No difference was observed regarding infection rates (RR 0.87, 95% CI 0.67- 1.09, I2 =0%, p=0.199). Revision rates were 8% (N=50/624) in the bolt group and 14% (N=148/1091) in the tunnelled group. There was no difference in revision rates (RR 0.54, 95% CI 0.17- 1.70, p=0.238). Obstruction rates were 9% (N=24/278) in the bolt group and 15% (N=61/394) in the tunnelled group. There was no difference in obstruction rates (RR 0.39, 95% CI 0.06-2.33, I2 =73%, p=0.232). No differences were observed in displacement (RR 0.39, 95% CI 0.06-2.33, I2 =73%, p=0.232), haemorrhage (RR 1.18, 95% CI 0.32-4.28, p=0.716), or optimal placement rates (RR 1.26, 95% CI 0.93-1.71, I2 = 40%, p=0.09).

Conclusions

Current evidence indicates that bolt-connected EVDs have equivalent outcomes compared to tunnelled EVDs and are non-inferior.

Zitieren

APA

Abbas, I., Ansari, T., Lau, M., Sivanesan, D., Brown, G., Cook, W., Lisitsyna, A., Kingham, M., Chedid, Y., Veremu, M., Karepov, Y., Viaroli, E., Lee, K., Craven, C., & Gillespie, C. (2026). 447 Bolt-Connected External Ventricular Drain Versus Tunnelled External Ventricular Drain: A Systematic Review and Meta-Analysis Comparing Accuracy and Complications. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.673

Vancouver

Abbas I, Ansari T, Lau M, Sivanesan D, Brown G, Cook W, et al. 447 Bolt-Connected External Ventricular Drain Versus Tunnelled External Ventricular Drain: A Systematic Review and Meta-Analysis Comparing Accuracy and Complications. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.673

BibTeX
@article{Abbas2026,
  author = {Abbas, I and Ansari, T and Lau, M and Sivanesan, D and Brown, G and Cook, W and Lisitsyna, A and Kingham, M and Chedid, Y and Veremu, M and Karepov, Y and Viaroli, E and Lee, K and Craven, C and Gillespie, C},
  title = {447 Bolt-Connected External Ventricular Drain Versus Tunnelled External Ventricular Drain: A Systematic Review and Meta-Analysis Comparing Accuracy and Complications},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.673}
}
Kostenlos starten →