EUVIMEDEUVIMED entdecken
Systematische Übersicht

369 Microsoft HoloLens in General Surgery: A New Era Systematic Review

L Jones-Whiting, H Mohamed, M Smith

British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)

DOI: 10.1093/bjs/znag063.669 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von L Jones-Whiting und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The Microsoft HoloLens mixed reality platform is increasingly used in surgical training and intraoperative guidance. This systematic review evaluated usability, workload, and accuracy (target registration error, TRE) across General surgery to inform the next era of mixed reality in the specialty.

Method

A PROSPERO-registered systematic review was conducted following PRISMA guidelines. Two reviewers independently screened titles, s, and full texts using Rayyan. Quantitative data (SUS, NASA-TLX, Likert satisfaction, TRE metrics, sample sizes) were extracted. A random-effects inverse-variance meta-analysis was performed for SUS. SDs were imputed when only IQRs were reported. TRE was summarised narratively due to heterogeneity in definitions, coordinate systems, and registration methods.

Results

Twenty studies were included, spanning models (40%), live participants (20%), patients (35%), and cadavers (5%). Subspecialties included surgical oncology (25%), education (20%), HPB (15%), and others. The mean SUS across all studies was 76.75, indicating good overall usability, consistent with the pooled meta-analytic estimate of 78.3 (95% CI 57.4–99.3). Heterogeneity was substantial (τ² = 60.8). Likert-style satisfaction scores (normalised 0–100%) demonstrated high user acceptability, with a mean of 81.33%, reflecting positive subjective experience. NASA-TLX scores averaged 34.4, representing moderate workload. TRE varied widely (1.6–13.7 mm) across differing registration approaches (manual, marker-based, marker-less) and experimental settings, preventing valid pooling and highlighting inconsistency in accuracy reporting.

Conclusions

MR technologies show good usability and high user satisfaction, with moderate workload. Accuracy remains highly variable due to non-standardised TRE methodologies. Harmonised reporting standards and unified accuracy metrics are required to advance MR into “A New Era” of surgery.

Zitieren

APA

Jones-Whiting, L., Mohamed, H., & Smith, M. (2026). 369 Microsoft HoloLens in General Surgery: A New Era Systematic Review. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.669

Vancouver

Jones-Whiting L, Mohamed H, Smith M. 369 Microsoft HoloLens in General Surgery: A New Era Systematic Review. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.669

BibTeX
@article{JonesWhiting2026,
  author = {Jones-Whiting, L and Mohamed, H and Smith, M},
  title = {369 Microsoft HoloLens in General Surgery: A New Era Systematic Review},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.669}
}
Kostenlos starten →