EUVIMEDEUVIMED entdecken
Crossref

1349 Adapting Systems to Improve Imaging Adequacy in Patients With Abdominal Aortic Aneurysm: A Quality Improvement Project

K Yalley, K Ecott, T Hardt

British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)

DOI: 10.1093/bjs/znag063.584 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von K Yalley und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Preoperative imaging is essential for planning abdominal aortic aneurysm (AAA) intervention. Variability in imaging protocols, particularly the omission of the thoracic aorta, can lead to missed pathology, delays in planning for complex endovascular repairs, repeat imaging, and increased exposure to contrast, radiation, and increased financial burden to the trust and the NHS ultimately.

Aim

To assess the adequacy of AAA imaging across the South Devon Vascular Network, identify the frequency and causes of repeat scans, and evaluate the impact of radiology request wording on scan quality.

Method

We retrospectively reviewed imaging for patients assessed for AAA intervention. We reviewed if imaging included aortic arch, wording of request and need for repeat imaging. Following first cycle, clinicians were asked to include ‘thoracic aorta’ in CT requests, and a new order entry (‘CT Whole Aorta’) was introduced on the EPIC system protocoled to include the aortic arch.

Results

Complete imaging of the aorta significantly improved from 45% in cycle 1 (n=80), to 80% in cycle 2 (n=60, p<0.0005). Repeat imaging decreased between cycles from 18% to 13% although not significantly (p=0.23) Requests specifically included thoracic aorta in 15% and 17% respectively.

Conclusions

Imaging completeness improved between cycles with a new protocol despite no significant improvement in wording of request. These findings suggest that sustainable improvements in imaging quality are best achieved through system-level changes rather than reliance on individual request detail. Embedding standardized protocols into referral workflows is essential to ensure consistently adequate imaging for AAA planning, reduce delays, and improve patient safety.

Zitieren

APA

Yalley, K., Ecott, K., & Hardt, T. (2026). 1349 Adapting Systems to Improve Imaging Adequacy in Patients With Abdominal Aortic Aneurysm: A Quality Improvement Project. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.584

Vancouver

Yalley K, Ecott K, Hardt T. 1349 Adapting Systems to Improve Imaging Adequacy in Patients With Abdominal Aortic Aneurysm: A Quality Improvement Project. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.584

BibTeX
@article{Yalley2026,
  author = {Yalley, K and Ecott, K and Hardt, T},
  title = {1349 Adapting Systems to Improve Imaging Adequacy in Patients With Abdominal Aortic Aneurysm: A Quality Improvement Project},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.584}
}
Kostenlos starten →