1022 Compliance With BSSH Flexor Tendon Repair Standards and Documentation Quality in a UK Regional Hand Unit: A 2023–2025 Service Evaluation
British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)
DOI: 10.1093/bjs/znag063.575 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von N Varma und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Aim
High-quality flexor tendon repair relies on adherence to BSSH operative standards and clear documentation to guide rehabilitation and optimise patient outcomes. This three-cycle audit assessed local compliance with BSSH standards and reviewed year-on-year improvements in operative documentation following implementation of SmartText, an EPR function supporting consistent data entry.
Method
A retrospective review was undertaken for 42 consecutive operations involving flexor tendon or multistructural hand trauma (Jan–Apr 2025). Variables evaluated included technique used, level of laceration, pulley preservation, neurovascular injury/repair documentation, and intra-operative tendon testing (IOTT). Documentation quality was assessed against an 11-point audit repeated in 2023, 2024 and in 2025 following SmartText introduction.
Results
Sixty-three flexor tendons were repaired, predominantly within zones 1–2 (83.8%). Compliance with BSSH standards was high: digit documented (92.8%), zone of laceration (71.4%), repair technique (88%), and pulley preservation/venting documentation (90.4%). Neurovascular injury and repair were consistently documented. IOTT occurred in 34.9% of cases, with satisfactory glide in all tested tendons. Findings showed ≥80% compliance in six standards, including site, digit, repair technique and pulley management. Neurovascular documentation improved from 87% (2023) to 100% (2025). The main persistent deficit was strand-number documentation (44% in 2024; 45% in 2025).
Conclusions
The unit shows strong adherence to BSSH operative standards with continued documentation improvements. Increasing IOTT use and improving strand-number recording remain key goals. Ongoing optimisation and induction-level training should support full compliance to improve postoperative management and patient outcomes. This audit demonstrates how SmartText tools could enhance operative documentation across all surgical specialties.
Zitieren
APA
Varma, N., Collinson, K., Wightman, M., Radcliffe, K., & Bedford, J. D. (2026). 1022 Compliance With BSSH Flexor Tendon Repair Standards and Documentation Quality in a UK Regional Hand Unit: A 2023–2025 Service Evaluation. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.575
Vancouver
Varma N, Collinson K, Wightman M, Radcliffe K, Bedford JD. 1022 Compliance With BSSH Flexor Tendon Repair Standards and Documentation Quality in a UK Regional Hand Unit: A 2023–2025 Service Evaluation. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.575
BibTeX
@article{Varma2026,
author = {Varma, N and Collinson, K and Wightman, M and Radcliffe, K and Bedford, J D},
title = {1022 Compliance With BSSH Flexor Tendon Repair Standards and Documentation Quality in a UK Regional Hand Unit: A 2023–2025 Service Evaluation},
journal = {British Journal of Surgery},
year = {2026},
volume = {113},
number = {Supplement_6},
doi = {10.1093/bjs/znag063.575}
}
EUVIMED