Background
Vascular access in patients with end-stage renal disease and central venous occlusion remains challenging. The super-HeRO (Haemodialysis Reliable Outflow) graft provides a durable solution for patients with central venous stenosis, while early-cannulation grafts such as the GORE Acuseal™ enable early initiation of dialysis. However, Super-HeRO grafts may be vulnerable to mechanical stress, particularly when cannulation technique is suboptimal. We report a rare case of inner layer dissection (delamination) of a GORE Acuseal™ graft within a Super-HeRO configuration. Case presentation A 61-year-old man with ESRD, diabetes, obesity, and ischaemic heart disease and multiple failed vascular access and central venous stenosis. He underwent a super-HeRO vascular access graft using a GORE Acuseal™ graft to allow early use. Although dialysis was initially successful for seven months, the graft developed repeated thrombosis despite two radiological thrombectomies. These episodes raised suspicion of structural graft failure, which was confirmed during surgical exploration. Intra-operative findings demonstrated inner layer delamination with formation of a false lumen. The damage was attributed to repeated cannulation leading to delamination. The affected segment was replaced, and the patient recovered well with a functioning graft at 14 months.
Discussion
Inner layer dissection of ePTFE grafts is rare but may mimic thrombosis or stenosis radiologically, delaying diagnosis. The graft delamination/dissection should be considered in patients with recurrent graft stenosis and thrombosis.
Zitieren
APA
Alhalawani, A., Mohideen, A. T., & Mittapalli, D. (2026). 957 Case Report: SUPER-HeRO Graft Delamination — a Rare Cause of Graft Dysfunction in Complex Dialysis Access. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.359
Vancouver
Alhalawani A, Mohideen AT, Mittapalli D. 957 Case Report: SUPER-HeRO Graft Delamination — a Rare Cause of Graft Dysfunction in Complex Dialysis Access. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.359
BibTeX
@article{Alhalawani2026,
author = {Alhalawani, A and Mohideen, A T and Mittapalli, D},
title = {957 Case Report: SUPER-HeRO Graft Delamination — a Rare Cause of Graft Dysfunction in Complex Dialysis Access},
journal = {British Journal of Surgery},
year = {2026},
volume = {113},
number = {Supplement_6},
doi = {10.1093/bjs/znag063.359}
}
EUVIMED