1418 Using ICG to Select Single Perforator Reduces Operative Time and Improves Outcomes in DIEP Reconstruction
British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)
DOI: 10.1093/bjs/znag063.300 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von S Benavides Laconcha und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Aim
Multiple perforators in DIEP flap reconstruction add complexity and increase operative times (linked to longer hospital stays) without clear benefit. We present our fledgling unit’s experience with Indocyanine Green (ICG) fluoroscopy as an adjunct to perforator selection to improve intra-operative efficiency.
Method
Data were prospectively gathered from April 2019, and ICG was used for all cases. Demographics included patient age, BMI, and indication for surgery. Intra-operative details included symmetrisation, flap ischaemic time, number of perforators, flap weight and total operative time. Outcome measures were flap survival, return to theatre (RTT) and length of stay (LOS).
Results
Between April 2019 and April 2025 142 DIEP flaps were performed in 122 patients. Mean age was 49 years (27-68) and mean BMI 27kg/m2 (19.2 – 40). 55% of DIEP flaps were immediate, 34% delayed and 11% risk reducing. 75% of patients underwent bilateral surgery (DIEP or symmetrising). 88% of flaps were single perforator, with an average flap weight of 624g (240 – 1319) and an average flap ischaemic time of 66 minutes (39 - 245). The average operating time was 291 minutes (236-509) and average LOS was 3.43 days (2 – 12). 11 patients required RTT, only one of which was for the contralateral breast.
Conclusions
Incorporating ICG fluoroscopy into perforator selection bolsters confidence in single perforator flaps, reducing flap manipulation and time spent unnecessarily isolating further perforators. In our unit this has translated to shorter operative times, earlier post-op mobilisation and briefer hospital stays, without sacrificing flap weight or symmetry.
Zitieren
APA
Laconcha, S. B., Cousins, L., Isaac, A., Hoo, C., & McGoldrick, C. (2026). 1418 Using ICG to Select Single Perforator Reduces Operative Time and Improves Outcomes in DIEP Reconstruction. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.300
Vancouver
Laconcha SB, Cousins L, Isaac A, Hoo C, McGoldrick C. 1418 Using ICG to Select Single Perforator Reduces Operative Time and Improves Outcomes in DIEP Reconstruction. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.300
BibTeX
@article{Laconcha2026,
author = {Laconcha, S Benavides and Cousins, L and Isaac, A and Hoo, C and McGoldrick, C},
title = {1418 Using ICG to Select Single Perforator Reduces Operative Time and Improves Outcomes in DIEP Reconstruction},
journal = {British Journal of Surgery},
year = {2026},
volume = {113},
number = {Supplement_6},
doi = {10.1093/bjs/znag063.300}
}
EUVIMED