848 Improving Compliance With Indwelling Catheter Securement in an Orthopedic Unit: A Two-Cycle Audit Against Best-Practice Standards
British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)
DOI: 10.1093/bjs/znag063.252 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von J Kankanamge G. Madhawa und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Aim
To assess compliance with evidence-based guidelines on securing indwelling urinary catheters in an orthopedic ward and evaluate the necessity of a targeted educational intervention. Major CAUTI-prevention guidelines (CDC and AHRQ) recommend applying a securement device during insertion and maintaining it throughout the catheter use. Based on these standards, a benchmark target of ≥90% appropriate catheter securement was expected.
Method
A two-cycle retrospective audit was conducted in a tertiary care orthopedic unit over four months per cycle. Data were collected on all catheterized inpatients, focusing on securement presence, site, and documentation. After the first cycle, a multifaceted intervention was implemented: structured teaching for nursing and junior medical staff on guideline-based securement practice, and introduction of a catheter care checklist incorporating securement as a mandatory item. A re-audit measured post-intervention compliance.
Results
86 patients were included in the initial cycle. Only 10.4% had appropriately secured catheters while 6.9 % of them were done intraoperatively and the rest in ICU setting. The majority of ward-inserted catheters had no securement, demonstrating major deviation from best-practice standards. After the intervention, 76 patients were reviewed in the re-audit, with appropriate securement improving to 40.7%, representing a near 4-fold increase but remaining below the ≥90% benchmark.
Conclusions
Lack of awareness of the importance of securing a catheter among the staff was identified as the main reason for suboptimal practice. A simple, low-cost intervention comprising staff education and checklist implementation produced substantial improvement. Sustained reinforcement and further cycles are required to achieve guideline-compliant practice and optimize patient comfort and safety.
Zitieren
APA
Madhawa, J. K. G., Peramuna, S., Naligama, A., Gnanasekeram, R., & Saranga, K. G. V. (2026). 848 Improving Compliance With Indwelling Catheter Securement in an Orthopedic Unit: A Two-Cycle Audit Against Best-Practice Standards. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.252
Vancouver
Madhawa JKG, Peramuna S, Naligama A, Gnanasekeram R, Saranga KGV. 848 Improving Compliance With Indwelling Catheter Securement in an Orthopedic Unit: A Two-Cycle Audit Against Best-Practice Standards. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.252
BibTeX
@article{Madhawa2026,
author = {Madhawa, J Kankanamge G. and Peramuna, S and Naligama, A and Gnanasekeram, R and Saranga, K G Vinod},
title = {848 Improving Compliance With Indwelling Catheter Securement in an Orthopedic Unit: A Two-Cycle Audit Against Best-Practice Standards},
journal = {British Journal of Surgery},
year = {2026},
volume = {113},
number = {Supplement_6},
doi = {10.1093/bjs/znag063.252}
}
EUVIMED