EUVIMEDEUVIMED entdecken
Crossref

Baseline Descending Aortic Diameter Drives Long-Term Failure of Conservative Management in Uncomplicated Type B Aortic Dissection

S Jungi, D Becker, H von Tengg-Kobligk, V Makaloski, D Kotelis

British Journal of Surgery · 03.06.2026 · 113 (Supplement_5)

DOI: 10.1093/bjs/znag055.068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 03.06.2026. Verfasst von S Jungi und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Failure of conservative management in patients with initially uncomplicated acute type B aortic dissection (TBAAD) remains clinically relevant.

Aims

This study evaluated whether commonly cited imaging-based morphologic features are associated with long-term failure of conservative management.

Methods

This retrospective single-center cohort study included consecutive patients treated for uncomplicated TBAAD between 2000 and 2018 with high-quality baseline computed tomography angiography and ≥1 year of imaging follow-up. Baseline morphologic parameters were assessed with centerline-based analysis and included descending thoracic aortic diameter (DTAD), ascending aortic diameter, true and false lumen dimensions, and primary entry tear (PET) characteristics (Fig. 1). Failure of conservative management was defined as the need for surgical or endovascular intervention >3 months after initial presentation. Cox proportional hazards models evaluated associations between morphologic parameters and subsequent intervention.

Results

Eighty-nine patients (median age 65 years; 65.2% male) were included with a median follow-up of 7.6 years. During follow-up, 33 patients (37.1%) required aortic intervention, mainly due to aneurysmal degeneration or rapid growth. Baseline DTAD was significantly larger in patients requiring intervention (median 41 mm vs. 37 mm; p=0.026). DTAD ≥40 mm was independently associated with intervention (adjusted hazard ratio [HR] 2.15; 95% confidence interval [CI] 1.05–4.42; p=0.037). DTAD analyzed as a continuous variable remained associated with intervention risk (HR 1.09 per mm; 95% CI 1.02–1.16; p=0.011). Other morphologic features were not associated with aortic growth or need for intervention.

Conclusion

Baseline descending thoracic aortic diameter was the only morphologic imaging feature consistently associated with long-term failure of conservative management in uncomplicated TBAAD.Fig. 1For image description, please refer to the figure legend and surrounding text.

Zitieren

APA

Jungi, S., Becker, D., Tengg-Kobligk, H. V., Makaloski, V., & Kotelis, D. (2026). Baseline Descending Aortic Diameter Drives Long-Term Failure of Conservative Management in Uncomplicated Type B Aortic Dissection. British Journal of Surgery, 113(Supplement_5). https://doi.org/10.1093/bjs/znag055.068

Vancouver

Jungi S, Becker D, Tengg-Kobligk HV, Makaloski V, Kotelis D. Baseline Descending Aortic Diameter Drives Long-Term Failure of Conservative Management in Uncomplicated Type B Aortic Dissection. British Journal of Surgery. 2026;113(Supplement_5). doi:10.1093/bjs/znag055.068

BibTeX
@article{Jungi2026,
  author = {Jungi, S and Becker, D and Tengg-Kobligk, H von and Makaloski, V and Kotelis, D},
  title = {Baseline Descending Aortic Diameter Drives Long-Term Failure of Conservative Management in Uncomplicated Type B Aortic Dissection},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_5},
  doi = {10.1093/bjs/znag055.068}
}
Kostenlos starten →