Autofluorescence-guided hemithyroidectomy in a low-volume thyroid institution with no experience in parathyroid surgery: randomized clinical trial
British Journal of Surgery · 2024
DOI: 10.1093/bjs/znae075 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift British Journal of Surgery, 2024. Verfasst von Ali Abood und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Goedstrup Hospital, Herning, Denmark. Hauptthemen laut MEDLINE: Thyroid Gland, Endocrine Surgical Procedures. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Health Research Foundation of Central Denmark Region, Center of Research and Education (NIDO; Goedstrup, Denmark, Skouby Foundation (Denmark).
Abstract (Originalsprache)
Background
Recent studies suggest that low-volume surgeons with no experience in parathyroid surgery are at increased risk of causing parathyroid gland damage during thyroid surgery. The aim of this RCT was to evaluate the impact of using autofluorescence in hemithyroidectomy on parathyroid gland identification and preservation in a low-volume institution with no experience in parathyroid surgery.
Methods
Patients referred for hemithyroidectomy were randomized 1 : 1 to either autofluorescence-guided hemithyroidectomy (the near-infrared autofluorescence group) or conventional hemithyroidectomy (the control group). The primary outcome was parathyroid gland identification rate. Secondary outcomes were the rate of parathyroid gland autotransplantation and the rate of inadvertent parathyroid gland excision.
Results
A total of 170 patients were randomized to either autofluorescence-guided hemithyroidectomy (84 patients) or conventional hemithyroidectomy (86 patients). In the near-infrared autofluorescence group, 81.0% of parathyroid glands were identified, compared with 57.0% in the control group (P < 0.001). Autofluorescence enabled parathyroid gland visualization before the naked eye in 46.3% of cases. Surgeons had lower confidence in the parathyroid gland identification process in the control group than in the near-infrared autofluorescence group (59.1% versus 87.5% respectively; P < 0.001). In the near-infrared autofluorescence group, the parathyroid gland autotransplantation rate was initially high, but declined over time. There was no difference in the rate of inadvertent parathyroid gland excision.
Conclusion
Autofluorescence guidance significantly improved the parathyroid gland identification rate in hemithyroidectomy in a low-volume institution with no experience in parathyroid surgery and provided an increase in surgical confidence. The pattern of parathyroid gland autotransplantation in autofluorescence-guided surgery indicates the presence of a learning curve. Registration number NCT05044351 (http://www.clinicaltrials.gov).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Goedstrup Hospital, Herning, Denmark.
- Department of Otorhinolaryngology, Head and Neck Surgery, Aarhus University Hospital, Aarhus, Denmark.
- Department of Pathology, Aarhus University Hospital, Aarhus, Denmark.
- Department of Endocrinology, Aalborg University Hospital, Aalborg, Denmark.
- Steno Diabetes Center North Denmark, Aalborg University Hospital, Aalborg, Denmark.
- Department of Thoracic and Endocrine Surgery, University Hospitals of Geneva, Geneva, Switzerland.
ORCID-Profile: Lars Rolighed, Frédéric Triponez
Förderung
- Health Research Foundation of Central Denmark Region
- Center of Research and Education (NIDO; Goedstrup, Denmark
- Skouby Foundation (Denmark)
Zitieren
APA
Abood, A., Rolighed, L., Ovesen, T., Madsen, S. H., Vestergaard, P., & Triponez, F. (2024). Autofluorescence-guided hemithyroidectomy in a low-volume thyroid institution with no experience in parathyroid surgery: randomized clinical trial. British Journal of Surgery. https://doi.org/10.1093/bjs/znae075
Vancouver
Abood A, Rolighed L, Ovesen T, Madsen SH, Vestergaard P, Triponez F. Autofluorescence-guided hemithyroidectomy in a low-volume thyroid institution with no experience in parathyroid surgery: randomized clinical trial. British Journal of Surgery. 2024. doi:10.1093/bjs/znae075
BibTeX
@article{Abood2024,
author = {Abood, Ali and Rolighed, Lars and Ovesen, Therese and Madsen, Stine H and Vestergaard, Peter and Triponez, Frédéric},
title = {Autofluorescence-guided hemithyroidectomy in a low-volume thyroid institution with no experience in parathyroid surgery: randomized clinical trial},
journal = {British Journal of Surgery},
year = {2024},
doi = {10.1093/bjs/znae075}
}
EUVIMED