Artificial intelligence and consistency in patient care: a large-scale longitudinal study of mammographic density assessment
BJR|Artificial Intelligence · 2025
DOI: 10.1093/bjrai/ubaf004 ↗Kurz gefasst
Fachartikel in der Zeitschrift BJR|Artificial Intelligence, 2025. Verfasst von Susan O Holley und 6 weiteren Autor:innen. Beteiligte Einrichtung: Onsite Women's Health, Nashville, TN 37203, United States. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, Barnes Jewish Hospital, Barnard Trust.
Abstract (Originalsprache)
Objectives
To assess whether use of an artificial intelligence (AI) model for mammography could result in more longitudinally consistent breast density assessments compared with interpreting radiologists.
Methods
The AI model was evaluated retrospectively on a large mammography dataset including 50 sites across the United States from an outpatient radiology practice. Examinations were acquired on Hologic imaging systems between 2016 and 2021 and were interpreted by 39 radiologists (36% fellowship trained; years of experience: 2-37 years). Longitudinal patterns in 4-category breast density and binary breast density (non-dense vs. dense) were characterized for all women with at least 3 examinations (61 177 women; 214 158 examinations) as constant, descending, ascending, or bi-directional. Differences in longitudinal density patterns were assessed using paired proportion hypothesis testing.
Results
The AI model produced more constant (P < .001) and fewer bi-directional (P < .001) longitudinal density patterns compared to radiologists (AI: constant 81.0%, bi-directional 4.9%; radiologists: constant 56.8%, bi-directional 15.3%). The AI density model also produced more constant (P < .001) and fewer bi-directional (P < .001) longitudinal patterns for binary breast density. These findings held in various subset analyses, which minimize (1) change in breast density (post-menopausal women, women with stable image-based BMI), (2) inter-observer variability (same radiologist), and (3) variability by radiologist’s training level (fellowship-trained radiologists).
Conclusions
AI produces more longitudinally consistent breast density assessments compared with interpreting radiologists. Advances in knowledge Our results extend the advantages of AI in breast density evaluation beyond automation and reproducibility, showing a potential path to improved longitudinal consistency and more consistent downstream care for screened women.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Onsite Women's Health, Nashville, TN 37203, United States.
- Whiterabbit.ai, Redwood City, CA 94065, United States.
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO 63110, United States.
- Division of Public Health Sciences, Department of Surgery, Washington University School of Medicine, St. Louis, MO 63110, United States.
- Siteman Cancer Center, Barnes-Jewish Hospital, Washington University School of Medicine, St. Louis, MO 63110, United States.
ORCID-Profile: Rodrigo Morales Hoil, Adetunji T Toriola, Aimilia Gastounioti
Förderung
- NCI NIH HHS
- Barnes Jewish Hospital
- Barnard Trust
- National Cancer Institute of the National Institutes of Health
Zitieren
APA
Holley, S. O., Cardoza, D., Matthews, T. P., Tibatemwa, E. E., Morales Hoil, R., Toriola, A. T., & Gastounioti, A. (2025). Artificial intelligence and consistency in patient care: a large-scale longitudinal study of mammographic density assessment. BJR|Artificial Intelligence. https://doi.org/10.1093/bjrai/ubaf004
Vancouver
Holley SO, Cardoza D, Matthews TP, Tibatemwa EE, Morales Hoil R, Toriola AT, et al. Artificial intelligence and consistency in patient care: a large-scale longitudinal study of mammographic density assessment. BJR|Artificial Intelligence. 2025. doi:10.1093/bjrai/ubaf004
BibTeX
@article{Holley2025,
author = {Holley, Susan O and Cardoza, Daniel and Matthews, Thomas P and Tibatemwa, Elisha E and Morales Hoil, Rodrigo and Toriola, Adetunji T and Gastounioti, Aimilia},
title = {Artificial intelligence and consistency in patient care: a large-scale longitudinal study of mammographic density assessment},
journal = {BJR|Artificial Intelligence},
year = {2025},
doi = {10.1093/bjrai/ubaf004}
}
EUVIMED