Fachartikel in der Zeitschrift BJR|Artificial Intelligence, 2024. Verfasst von Ramesh Paudyal und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS, NIGMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Auto-segmentation promises greater speed and lower inter-reader variability than manual segmentations in radiation oncology clinical practice. This study aims to implement and evaluate the accuracy of the auto-segmentation algorithm, “Masked Image modeling using the vision Transformers (SMIT),” for neck nodal metastases on longitudinal T2-weighted (T2w) MR images in oropharyngeal squamous cell carcinoma (OPSCC) patients.

Methods

This prospective clinical trial study included 123 human papillomaviruses (HPV-positive [+]) related OSPCC patients who received concurrent chemoradiotherapy. T2w MR images were acquired on 3 T at pre-treatment (Tx), week 0, and intra-Tx weeks (1-3). Manual delineations of metastatic neck nodes from 123 OPSCC patients were used for the SMIT auto-segmentation, and total tumor volumes were calculated. Standard statistical analyses compared contour volumes from SMIT vs manual segmentation (Wilcoxon signed-rank test [WSRT]), and Spearman’s rank correlation coefficients (ρ) were computed. Segmentation accuracy was evaluated on the test data set using the dice similarity coefficient (DSC) metric value. P-values <0.05 were considered significant.

Results

No significant difference in manual and SMIT delineated tumor volume at pre-Tx (8.68 ± 7.15 vs 8.38 ± 7.01 cm3, P = 0.26 [WSRT]), and the Bland-Altman method established the limits of agreement as –1.71 to 2.31 cm3, with a mean difference of 0.30 cm3. SMIT model and manually delineated tumor volume estimates were highly correlated (ρ = 0.84-0.96, P < 0.001). The mean DSC metric values were 0.86, 0.85, 0.77, and 0.79 at the pre-Tx and intra-Tx weeks (1-3), respectively.

Conclusions

The SMIT algorithm provides sufficient segmentation accuracy for oncological applications in HPV+ OPSCC. Advances in knowledge First evaluation of auto-segmentation with SMIT using longitudinal T2w MRI in HPV+ OPSCC.

Schlagwörter

Stichwörter der Autor:innen

auto-segmentationconvolutional neural networkdeep learningneck nodal metastasesself-supervised learningvision transformers

Autor:innen und Institutionen

  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States.
  • Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States.
  • Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, United States.

ORCID-Profile: Ramesh Paudyal, Nadeem Riaz, Joseph O Deasy, Amita Shukla-Dave

Förderung

  • NCI NIH HHS
  • NIBIB NIH HHS
  • NIGMS NIH HHS
  • NIH
  • NCI Cancer Center

Zitieren

APA

Paudyal, R., Jiang, J., Han, J., Diplas, B. H., Riaz, N., Hatzoglou, V., Lee, N., Deasy, J. O., Veeraraghavan, H., & Shukla-Dave, A. (2024). Auto-segmentation of neck nodal metastases using self-distilled masked image transformer on longitudinal MR images. BJR|Artificial Intelligence. https://doi.org/10.1093/bjrai/ubae004

Vancouver

Paudyal R, Jiang J, Han J, Diplas BH, Riaz N, Hatzoglou V, et al. Auto-segmentation of neck nodal metastases using self-distilled masked image transformer on longitudinal MR images. BJR|Artificial Intelligence. 2024. doi:10.1093/bjrai/ubae004

BibTeX
@article{Paudyal2024,
  author = {Paudyal, Ramesh and Jiang, Jue and Han, James and Diplas, Bill H and Riaz, Nadeem and Hatzoglou, Vaios and Lee, Nancy and Deasy, Joseph O and Veeraraghavan, Harini and Shukla-Dave, Amita},
  title = {Auto-segmentation of neck nodal metastases using self-distilled masked image transformer on longitudinal MR images},
  journal = {BJR|Artificial Intelligence},
  year = {2024},
  doi = {10.1093/bjrai/ubae004}
}
Kostenlos starten →